background image

8312-A2-GZ40-30

December 2000

3

Installing the 8312/8314 Card

Procedure

To install the Hotwire 8312/8314 MVL or ReachDSL/MVL Card in a Hotwire 
chassis:

1. If there is a filler plate covering the slot, remove it.

2. Insert the card into the card guides of the slot on the chassis. For the 

8610 DSLAM, ensure that the components are facing up.

3. Carefully slide the card into the slot. Gently, but firmly, push the card until it 

engages its mating connectors on the backplane.

4. Verify that the OK SYSTEM indicator on the card’s faceplate is ON (green). 

If not, refer to the appropriate chassis installation document.

5. Secure the card by fastening the screws on each end of the faceplate. This is 

required to maintain proper gasket pressure on the faceplate as well as proper 
air flow.

Содержание Hotwire 8312

Страница 1: ...iber Line Access Multiplexer DSLAM or 8620 8820 GranDSLAM chassis and connected to the Hotwire 6310 MVL Modem it provides high speed Internet or intranet access over traditional twisted pair telephone wiring The 8312 8314 ReachDSL MVL cards are based on the 8312 8314 MVL cards and provide the following enhancements Maximum on hook Tx power is increased from 10 to 12dB Maximum off hook Tx power is ...

Страница 2: ...ped with one of the following installation documents Refer to one of the above installation documents to Install and set up the Hotwire DSLAM or GranDSLAM chassis Install the Hotwire 8312 8314 MVL or ReachDSL MVL card Connect cables After the card is installed there are configuration procedures that must be performed before you can begin to use the cards for Internet or intranet connectivity Refer...

Страница 3: ...8610 DSLAM ensure that the components are facing up 3 Carefully slide the card into the slot Gently but firmly push the card until it engages its mating connectors on the backplane 4 Verify that the OK SYSTEM indicator on the card s faceplate is ON green If not refer to the appropriate chassis installation document 5 Secure the card by fastening the screws on each end of the faceplate This is requ...

Страница 4: ...RNET TX Green Blinking Off A packet is being sent LED blinks on and off about five times per second Inactive RX Green Blinking Off A packet is being received LED blinks on and off about five times per second Inactive Coll Off Yellow Blinking Normal operation A collision has been detected LED blinks on and off 2 4 times per second PORT 1 12 Green On Off Green Blinking Green Reverse Winking DSL link...

Страница 5: ...n Blinking Off Card has placed cells on the backplane bus LED blinks on and off 2 4 times per second Inactive RX Green Blinking Off Card has received cells from the backplane bus LED blinks on and off 2 4 times per second Inactive LOC Off Yellow On Normal operation Card not receiving a clock signal from the GranDSLAM backplane bus DSL PORT 1 12 Green On Off Green Blinking Green Reverse Winking DSL...

Страница 6: ...to the equipment s label for approvals on product Power Maximum Power Dissipation MVL 8312 MVL 8314 ReachDSL MVL 8312 ReachDSL MVL 8314 The card contains a DC to DC converter that requires 48V nominal power input 40 0 to 60 0 VDC The 48V power is distributed through the chassis backplane 13 4 watts 15 2 watts 14 4 watts 16 2 watts Physical Environment Operating temperature Storage temperature Rela...

Страница 7: ...1 727 530 2340 Document Feedback We welcome your comments and suggestions about this document Please mail them to Technical Publications Paradyne Corporation 8545 126th Ave N Largo FL 33773 or send e mail to userdoc paradyne com Include the number and title of this document in your correspondence Please include your name and phone number if you are willing to provide additional clarification Trade...

Отзывы: