background image

13

10.

This unit is provided with a replaceable lithium battery. Replace the battery only with 
the same type recommended by the manufacturer. Discard used batteries 
according to the manufacturer’s instructions.

Supplier’s Declaration of Conformity

Place of Issue: Paradyne Corporation

8545 126

th

 Avenue North

Largo, FL 33773-1502
USA

Date of Issue:

4/4/2003

Paradyne Corporation, located at the above address, hereby certifies that the Hotwire® 
Model Number 8300-AX-400, bearing labeling identification number 
US:AW2DLNAN8300-AX complies with: the Federal Communications Commission's 
("FCC") Rules and Regulations 47 CFR Part 68, the Administrative Council on Terminal 
Attachments ("ACTA")-adopted technical criteria: TIA-968-A, "Telecommunications - 
Telephone Terminal Equipment -Technical Requirements for Connection of Terminal 
Equipment To the Telephone Network, October 2002" and T1.TRQ.6-2001, "Technical 
Requirements for SHDSL, HDSL2, HDSL4 Digital Subscriber Line Terminal Equipment 
to Prevent Harm to the Telephone Network."

Patrick Murphy

Senior Vice President, Chief Financial Officer

Warranty, Sales, Service, and Training Information

Contact your local sales representative, service representative, or distributor directly for 
any help needed. For additional information concerning warranty, sales, service, repair, 
installation, documentation, training, distributor locations, or Paradyne worldwide office 
locations, use one of the following methods:

Internet:

 Visit the Paradyne World Wide Web site at 

www.paradyne.com

. (Be 

sure to register your warranty at 

www.paradyne.com/warranty

.)

Telephone:

 Call our automated system to receive current information by fax or to 

speak with a company representative.

Within the U.S.A., call 1-800-870-2221

Outside the U.S.A., call 1-727-530-2340

Содержание Hotwire 8300

Страница 1: ...Users of the Canadian Telephone Network 11 Important Safety Instructions 12 Supplier s Declaration of Conformity 13 Warranty Sales Service and Training Information 13 Document Feedback 14 Trademarks 1...

Страница 2: ...nt A clean well lit and ventilated site that is free from environmental extremes One to two feet of clearance for cable connections An asynchronous terminal or PC A physical connection to the G shdsl...

Страница 3: ...Plug the other end of the power cord into a grounded power outlet 3 Check the LEDs When power is applied to the unit the front panel indicators flash for approximately 10 to 15 seconds as the unit in...

Страница 4: ...g received NET The indicator is off not illuminated when the Network port has not been configured The indicator lights green when the Network port link is up and the ATM protocol is established The in...

Страница 5: ...rvisory interface screen A VT100 terminal or a PC providing VT100 terminal emulation must be used to set up access to and management of the unit Procedure 1 Configure the PC so it is compatible with t...

Страница 6: ...e are two unlabeled indicator LEDs on either side of the 10 100 ETHERNET jack The LED on the left side of the jack pulses amber to indicate data activity either transmit or receive The LED on the righ...

Страница 7: ...ptation Layer 1 with Circuit Emulation Services AAL1 CES It must not be connected to outside plant wiring Procedure 1 Plug an RJ48 to RJ48 cable not provided into the CBR port 2 Plug the other end of...

Страница 8: ...ting the Ethernet Port Address To set the Ethernet port address Procedure 1 Access the Main Menu as described in Connecting the Supervisory Port on page 5 2 Tab to the Interfaces selection and press E...

Страница 9: ...ion 5 0 or higher is recommended 2 Type the IP address of the 8300 Endpoint s Ethernet port into the Address field of the browser and press Enter The Unit Screen appears Click on the selections in the...

Страница 10: ...is equipment is intended to connect to the Telephone Network through a Universal Service Order Code USOC type RJ49C A plug and jack used to connect this equipment to the premises wiring and telephone...

Страница 11: ...erence causing equipment regulations Cet appareil num rique de la classe A respecte toutes les exigences du r glement sur le mat rial brouilleur du Canada Notices to Users of the Canadian Telephone Ne...

Страница 12: ...pecial cables which may be required by the regulatory inspection authority for the installation site are the responsibility of the customer To reduce the risk of fire use a UL Listed or CSA Certified...

Страница 13: ...uirements for Connection of Terminal Equipment To the Telephone Network October 2002 and T1 TRQ 6 2001 Technical Requirements for SHDSL HDSL2 HDSL4 Digital Subscriber Line Terminal Equipment to Preven...

Страница 14: ...ber and title of this document in your correspondence Please include your name and phone number if you are willing to provide additional information Trademarks FrameSaver is a registered trademark of...

Страница 15: ...15...

Страница 16: ...16 8300 A2 GN10 00 8300 A2 GN10 00...

Отзывы: