Troubleshooting

To improve data transmission throughput and minimize background noise during a 
telephone conversation, make sure that:

„

The Hotwire 6390 ReachDSL Modem is always powered on, even when not in 
use, and

„

A Hotwire phone filter is installed on every telephone on the same line as the 
Hotwire 6390 ReachDSL Modem (refer to the 

Hotwire ReachDSL Modem, 

Model 6390 with Inline Phone Filter, Installation Instructions

Document 

Number 6390-A2-GN10).

LED Symptom

Action

All LEDs are on.

If LEDs remain on after ten minutes, the modem is not functional. 
Contact the service provider.

ALM LED remains 
on.

The power-on self-test may have failed. Unplug the unit and 
reapply power. If the alarm LED is still on, contact the service 
provider.

Ethernet LED is off.

Verify that the Ethernet cable is securely installed at both ends, and 
at least one PC is connected and powered on.

Verify that the correct straight-through or crossover cable is 
installed. Refer to 

Cables & Connectors

 on page 6.

LINE LED is off.

Verify that the DSL LINE cable is securely installed on both ends. If 
the problem continues, contact the service provider.

Verify that the line has dial tone. If there is no dial tone, contact the 
service provider.

LINE LED is on and 
there is no data 
transmission.

The DSL link has been established but there is no data 
transmission. Verify the Ethernet connection. If the problem 
persists, contact the service provider.

LINE and Ethernet 
LEDs are on and 
there is no data 
transmission.

The DSL and Ethernet links have been established but there is no 
data transmission. If the problem continues, contact the service 
provider.

PWR LED is off.

Check that the power cord is securely installed on both ends.

If no LEDs are on, the power supply may be defective. Test the 
outlet to verify power. If the problem persists, contact the service 
provider.

If other LEDs are on, the PWR LED may be burned out. Unplug the 
unit and reapply power; watch all LEDs during the power-on 
self-test to verify if the PWR LED is functioning.

TST LED is on.

A test initiated by the service provider may be active. Wait five 
minutes. If the TST LED does not go off, contact the service 
provider.

Содержание Hotwire 6390

Страница 1: ...ubleshooting 5 Increasing the Number of End User Systems 6 Optional ReachDSL Modem Wall Placement 8 ReachDSL Modem Hardware Template 9 Hotwire 6390 ReachDSL Modem Commands 10 Downloading Hotwire 6390 ReachDSL Modem Software 11 Building a Management PVC to the Model 8355 Line Card in an 8820 GranDSLAM Network 12 Building a Management PVC through the 4200 GranDSLAM System 14 Downloading Software to ...

Страница 2: ...r telephone wiring The ReachDSL technology Operates over existing copper wire with existing telephone jacks Uses an inline phone filter on the modem s PHONE jack Includes a second line pass through from the ReachDSL modem s LINE jack to PHONE jack to accommodate an attached 2 line telephone Provides adaptive data rates to dynamically adapt and allocate bandwidth to optimize applications Refer to t...

Страница 3: ... user system is used to represent any PC with an Ethernet connection and ReachDSL based service RJ11 wall jack is used to represent either an RJ11 or an RJ14 wall jack The RJ14 wall jack is used for a phone with two lines Service provider is used to represent any Internet Service Provider ISP or remote LAN access provider 02 17237 ReachDSL Modem Customer Premises CP DSL POTS Standard Ethernet Cabl...

Страница 4: ...ETHERNET ALM PWR TX RX 01 17003 Power green Alarm red Test yellow Transmit Receive green Ethernet Link green DSL Line green LED Condition Status PWR ON ReachDSL modem has power ALM OFF ON No active alarms An alarm condition exists TST OFF ON No active tests The TST LED is on during the power on self test and during a test initiated by the service provider LINE ON OFF The DSL link is active and rea...

Страница 5: ...s Connectors on page 6 LINE LED is off Verify that the DSL LINE cable is securely installed on both ends If the problem continues contact the service provider Verify that the line has dial tone If there is no dial tone contact the service provider LINE LED is on and there is no data transmission The DSL link has been established but there is no data transmission Verify the Ethernet connection If t...

Страница 6: ...er DSL port and the Hotwire ReachDSL Modem supports up to 256 MAC entries Cables Connectors Standard twisted pair CAT3 or better cables are recommended The LINE and PHONE interface connectors use 6 pin non keyed modular plugs RJ11 or RJ14 6 pin connectors can be used Line Phone Connectors The LINE and PHONE jack pinouts are either filtered or unfiltered for POTS Pin Function 1 Not used 2 Ring 2 op...

Страница 7: ...o connect the DSL modem to an uplink port on an Ethernet hub or PC with an Ethernet NIC card use the straight through connection 8 Pin Straight through Connection Pin Function 1 10BaseT RXD 2 10BaseT RXD 3 10BaseT TXD 4 5 Not used 6 10BaseT TXD 7 8 Not used 98 16055a 8 Pin Plug Ethernet Cable Pin 1 Pin 8 ...

Страница 8: ...hors Drill and 3 16 drill bit for the plastic anchors Screwdriver A template with the dimensions for the two screws is provided See ReachDSL Modem Hardware Template on page 9 Procedure To mount the Hotwire 6390 ReachDSL Modem 1 Use a drill to install the plastic anchors 2 Use a screwdriver to install the screws Do not install the screws flush with the wall Leave enough clearance to hang the modem ...

Страница 9: ...6390 A2 GK40 00 September 2002 9 ReachDSL Modem Hardware Template 12 95 cm or 5 10 02 17014 01 Top Bottom ...

Страница 10: ...irmware Revision Hardware Revision DSP Revision logoff None Terminates the Telnet session mgmtpvc dhcp IP address gateway No argument dhcp or ip address dhcp Example mgmtpvc dhcp IP address gateway Example mgmtpvc 135 26 95 1 135 26 95 6 Configures or displays the management PVC Current configuration Configures the management PVC The management PVC acquires its address using DHCP The management PV...

Страница 11: ...8820 GranDSLAM network with a Model 8355 Line Card or a 4200 GranDSLAM network See the following for procedures Building a Management PVC to the Model 8355 Line Card in an 8820 GranDSLAM Network on page 12 Building a Management PVC through the 4200 GranDSLAM System on page 14 Downloading Software to the ReachDSL Modem on page 15 upgrade IP address m e remote file name IP address m or e m e Remote ...

Страница 12: ...ss of 135 26 6 xxx with a Class C subnet mask For more information on the Model 8355 line card see the Hotwire ATM Line Cards Models 8335 8355 8365 and 8385 User s Guide Document Number 8335 A2 GB20 Figure 1 Network View of Hotwire 6390 ReachDSL Modem Software Download in an 8820 GranDSLAM System ALARMS Major Minor Fan B A POWER SERIAL SMCM CLOCK A ALARM 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 1...

Страница 13: ...ine card as shown below 3 Select the Cross Connect Sorted by Slot screen from SCM card Follow this menu selection sequence Configuration ATM Switch Cross Connect Sorted by Slot A E B B 4 Define the custom cross connect table on the SCM card using the last three digits of the Connection Serial Number CSN from the Model 8355 line card Cross Connect screen In this example use the 002 portion of the 1...

Страница 14: ...ic mode using the mgmtpvc command see Table 1 Hotwire ReachDSL 6390 Modem Commands via a PC attached to the 6390 modem s Ethernet port The PC must have an IP address of 135 26 6 xxx with a Class C subnet mask For more information on the GranDSLAM 4200 and CLI commands see the GranDSLAM 4200 ATM Stackable DSLAM User s Guide Document Number 4200 A2 GB20 Figure 2 Network View of Hotwire 6390 ReachDSL...

Страница 15: ...n the upstream ATM network NT and Port 1 LT using the ENT CRS VC command For example type ENT CRS VC TAMPA NTVCL 1 33 LTVCL 1 1 1 1 0 33 100 IS 5 Define a management PVC path across the ATM network to reach the GranDSLAM 4200 1 33 uplink management PVC using 1483 routed encapsulation 6 Ping the Hotwire 6390 ReachDSL Modem Management IP address assigned by the DHCP server DHCP mode or manually Stat...

Страница 16: ... Approvals FCC Part 15 CISPR 22 Other Certifications Class B digital device Class B Refer to equipment s label for approvals on product Physical Environment Operating temperature Storage temperature Relative humidity Shock and vibration 0 C to 40 C 32 F to 104 F 30 C to 70 C 22 F to 158 F 5 to 95 noncondensing Withstands normal shipping and handling Heat Dissipation 2 35 watts at 5 0 VDC nominal i...

Страница 17: ...pany representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about this document Please mail them to Technical Publications Paradyne Corporation 8545 126th Ave N Largo FL 33773 or send e mail to userdoc paradyne com Include the number and title of this document in your correspondence Please include your na...

Страница 18: ... 6390 A2 GK40 00 ...

Отзывы: