14                                                                      September 2004                                                      6205-A2-GZ40-10 

energy and, if not installed and used in accordance with the instructions, may cause harmful interference 
to radio communications. However, there is no guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference to radio or television reception, which can 
be determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:  

• 

Reorient or relocate the receiving antenna. 

• 

Increase the separation between the equipment and receiver. 

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected. 

• 

Consult the dealer or an experienced radio/TV technician for help. 

 

Notice to Users of the United States Telephone Network 

The following notice applies to versions of the modem that have been FCC Part 68 approved. 
This equipment complies with Part 68 of the FCC rules and the requirements adopted by the 
Administrative Council for Terminal Attachment (ACTA). On the bottom side of this equipment is a label 
that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If 
requested, this number must be provided to the Telephone Company. 
This equipment is intended to connect to the Public Switched Telephone Network through a Universal 
Service Order Code (USOC) type RJ11C jack. A plug and jack used to connect this equipment to the 
premises wiring and telephone network must comply with the applicable FCC Part 68 rules and 
requirements adopted by the ACTA. A compliant telephone cord and modular plug is provided with this 
product. It has been designed to be connected to a compatible modular jack that is also compliant. 
The Ringer Equivalence Number (or REN) is used to determine the number of devices that may be 
connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing 
in response to an incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). 
To be certain of the number of devices that may be connected to a line, as determined by the total RENs, 
contact the local Telephone Company. The REN for this product is part of the product identifier that has 
the format US:AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point. For 
example, 03 represents a REN of 0.3. 
If the modem causes harm to the telephone network, the Telephone Company will notify you in advance 
that temporary discontinuance of service may be required. But if advance notice is not practical, the 
Telephone Company will notify the customer as soon as possible. Also, you will be advised of your right 
to file a complaint with the FCC if you believe it is necessary. 
The Telephone Company may make changes in its facilities, equipment, operations or procedures that 
could affect the operation of the equipment. If this happens, the Telephone Company will provide 
advance notice in order for you to make necessary modifications to maintain uninterrupted service. If 
trouble is experienced with the modem, refer to the repair and warranty information in this document. 
If the equipment is causing harm to the telephone network, the Telephone Company may request that 
you disconnect the equipment until the problem is resolved. 
The user may make no repairs to the equipment. 
Connection to party line service is subject to state tariffs. Contact the state public utility commission, 
public service commission or corporation commission for information. 
If the site has specially wired alarm equipment connected to the telephone line, ensure the installation of 
the modem does not disable the alarm equipment. If you have questions about what will disable alarm 
equipment, consult your Telephone Company or a qualified installer. 

Notice to Users of the Canadian Telephone Network 

NOTICE: This equipment meets the applicable Industry Canada Terminal Equipment Technical 
Specifications. This is confirmed by the registration number. The abbreviation IC before the registration 
number signifies that registration was performed based on a Declaration of Conformity indicating that 

Содержание Hotwire 6205

Страница 1: ...L Modem offers up to 8 Mbps downstream and 800 kbps upstream A Plug N Play USB port provides Internet connectivity to your PC The Hotwire 6205 ADSL Modem supports Windows 98FE SE Windows 2000 Windows Millennium and Windows XP System Requirements In order to use the Hotwire 6205 ADSL Modem for Internet access you must have the following ADSL service subscription from your Internet Service Provider ...

Страница 2: ...2 September 2004 6205 A2 GZ40 10 Package Contents Your Hotwire 6205 ADSL Modem package includes Hotwire 6205 unit RJ11 ADSL cable USB Cable CD ROM ...

Страница 3: ...em is powered ON Your Modem is powered OFF WAN Yellow On Blinking Off Up Connected successfully Handshaking The modem is trying to connect Down Disconnected DATA Yellow Blinking Data transfer over ADSL line Rear Panel The rear panel contains the ports for the unit s data and power connections Port Description USB USB port to your PC LINE RJ11 outlet for ADSL line connection ...

Страница 4: ...on Filter Connect Line Filter Optional 1 Unplug the phone cable from the phone jack of your phone and plug it into the WALL jack of the Y Line Filter 2 Plug the ADSL cable into the ADSL jack of the Y Line Filter and the Modem 3 Plug another phone cable into the PHONE jack of the Y Line Filter and your phone Warning DO NOT CONNECT THE USB CABLE INTO THE UNIT UNTIL THE DRIVER INSTALLATION IS COMPLET...

Страница 5: ...rt the provided CD The CD should automatically start the driver installation If autorun is disabled double click Setup exe in the root directory of the CD 2 Click on OK when the Information pop up window appears 3 Click on Next when the modem setup windows appears ...

Страница 6: ...6 September 2004 6205 A2 GZ40 10 4 Choose the proper driver type MPoA Bridge Routed or PPPoA PPPoE Then click Next ...

Страница 7: ...6205 A2 GZ40 10 September 2004 7 ...

Страница 8: ... there might be a pop up message to remind you to plug in USB modem Click on OK and plug in your USB modem 7 After you attach the USB modem to your computer there will be a small triangle icon on the right bottom taskbar of your screen If there is no ADSL connection it will be red If the ADSL connection is established it will be green ...

Страница 9: ...A2 GZ40 10 September 2004 9 8 If you install PPPoA PPPoE there will be a dial up icon in your desktop to connect your ISP Please contact your ISP to get the correct user name and password for Internet access ...

Страница 10: ...10 September 2004 6205 A2 GZ40 10 USB Driver Uninstallation 1 Click on Uninstall from Windows Start menu 2 Keep your modem connected and click on OK 3 Click on Finish to complete the Uninstallation ...

Страница 11: ...6205 A2 GZ40 10 September 2004 11 4 Unplug your USB modem and click on OK ...

Страница 12: ...r describes how to obtain Hotwire 6205 system information when you double click the small triangle icon on the right bottom of the taskbar After you click the icon you ll see the status page which will tell you that the modem is idle handshaking or operational ...

Страница 13: ...nications circuits take the following precautions Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines Avoid...

Страница 14: ...ing call In most but not all areas the sum of RENs should not exceed five 5 0 To be certain of the number of devices that may be connected to a line as determined by the total RENs contact the local Telephone Company The REN for this product is part of the product identifier that has the format US AAAEQ TXXXX The digits represented by are the REN without a decimal point For example 03 represents a...

Страница 15: ...erface The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed five If your equipment is in need of repair contact your local sales representative service representative or distributor directly CANADA EMI NOTICE This Class B digital apparatus meets all requirements of...