background image

TM

 1

Hotwire

 5546 RTU Customer Premises

Installation Instructions

Document Number 5546-A2-GN10-00

September 1998

Before You Begin

The Hotwire

 5546 RTU (Remote Termination Unit) interoperates with the Hotwire

8546 DSL Card in the DSLAM system. Verify that the 8546 DSL card has Firmware
Release 2.2 or higher.

An optional POTS (Plain Old Telephone Service) splitter is available for the Hotwire
5546 RTU. When a POTS splitter is installed, the telephone and 5546 RADSL (Rate
Adaptive Digital Subscriber Line) RTU can function at the same time over the same pair
of copper wires. In order to confirm the RTU installation, the POTS splitter should be
installed first.

To install a POTS splitter, refer to the appropriate POTS splitter document:

Document Number

Document Title

5030-A2-GN10

Hotwire 5030 POTS Splitter Customer Premises 
Installation Instructions

5038-A2-GN10

Hotwire 5038 Distributed POTS Splitter Customer
Premises Installation Instructions

Contact your sales or service representative to order additional product documentation.
Paradyne documents are also available on the World Wide Web at:

http://www.paradyne.com

Select 

Service & Support 

 Technical Manuals

Package Checklist

Verify that your package contains the following:

Model 5546 Remote Termination Unit (RTU)

DSL interface cable with RJ11 connectors

RJ45 to DB9 adapter plug (Part No. 002-0093-0031)

One ferrite choke (Model 5546-A1-200 only)

Power cord with power transformer

Warranty card

Содержание Hotwire 5546

Страница 1: ...splitter should be installed first To install a POTS splitter refer to the appropriate POTS splitter document Document Number Document Title 5030 A2 GN10 Hotwire 5030 POTS Splitter Customer Premises...

Страница 2: ...and a telephone can function simultaneously over the same pair of copper wires when either H A Hotwire 5030 POTS Splitter is installed near the demarcation point for all telephones on the same POTS li...

Страница 3: ...ms DSL Access with a Hotwire 5038 Distributed POTS Splitter When a Hotwire 5038 Distributed POTS Splitter is used one 5038 Distributed POTS Splitter is installed as a filter for each telephone on the...

Страница 4: ...access 98 15614 02 Punchdown Block or NID DSL Jack RTU Customer Premises CP POTS DSL Central Office CO Network Service Provider NSP Demarcation Point Local Loop Router New Wiring Connections Existing...

Страница 5: ...in residential locations Procedure 1 Access the punchdown block or NID WARNING Do not continue unless the DSL access line from the local loop has been disconnected at the NID or punchdown block Refer...

Страница 6: ...In the following example a NID is used without a POTS splitter It includes an existing POTS line and a second pair installed for DSL access DSL POTS Access from Local Loop Wiring to DSL Jack Telephon...

Страница 7: ...a single jack with a double RJ11 jack 97 15343 02 DSL RJ11 Jack Central Office Punchdown Block or NID Customer Premises POTS DSL Local Loop Demarcation Point DSL Twisted pair Wiring RTU Procedure 1 Wi...

Страница 8: ...5546 RTU is installed on the same line as POTS a Hotwire 5038 Distributed POTS Splitter can be used as a filter One 5038 Distributed POTS splitter is installed as a filter for each telephone as shown...

Страница 9: ...ange the DTE configuration defaults or to download software This connection can be temporary and disconnected after the changes are completed See Hotwire 5546 RTU Configuration Setup page 12 The Conso...

Страница 10: ...h the ferrite choke twice creating a loop as shown 98 16130 5 Close the two halves around the cable and snap the ferrite choke shut Press down on the plastic latch to secure the ferrite choke in place...

Страница 11: ...ata Terminal Ready green 5546 Refer to Troubleshooting page 14 for LED indications requiring action Status LEDs After a successful self test the LEDs should appear as indicated in BOLD in the Conditio...

Страница 12: ...ears with the following default settings DTE Configuration Electrical Interface V35 Local Loopback OFF TX Timing Source DCE TX Data Strobe POSITIVE HW Model X Serial No X HW Revision X FW Version X If...

Страница 13: ...The DTE clock is used for the RTU Transmit Timing Source The DCE generates an internal synchronous clock for the RTU Transmit Timing Source TX Data Strobe POSITIVE NEGATIVE Clocking uses positive edg...

Страница 14: ...re on and there is no data transmission The DSL and DTR links have been established but there is no data transmission If the problem persists contact the NSP DSL and DTR LEDs are off Firmware download...

Страница 15: ...modular plug RJ11 6 Pin Connector Pin Function 1 2 Not used 3 DSL Ring 4 DSL Tip 5 6 Not used The Console connector uses an 8 pin RJ45 non keyed modular plug and DB9 adapter Only use this connection w...

Страница 16: ...D DCE Ready DSR 6 From RTU Out E Signal Ground SG 7 B Received Line Signal Detector DCD 8 From RTU Out F Receiver Timing DTE RxC 9 To RTU In X Received Line Signal Detector DCD 10 From RTU Out Transm...

Страница 17: ...17 The EIA 530A to V 35 Adapter Cable provides the V 35 interface shown below The V 35 cable includes a 25 pin to 34 pin adapter 98 16045 Pin 1 DB25 Pin A Pin NN MS34...

Страница 18: ...lass B Subpart B digital device Class A Refer to equipment s label for approvals on product Physical Environment Operating temperature Storage temperature Relative humidity Shock and vibration 32 F to...

Страница 19: ...ction authorities to ensure compliance 7 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnec...

Страница 20: ...or use within certain voltage limits as amended by Directive 93 68 EEC Directive 89 336 EEC Council Directive of 3 May 1989 on the approximation of the laws of the member states relating to Electro Ma...

Страница 21: ...his device must accept any interference received including interference that may cause undesired operation The name address and telephone number of the responsible party is given below Paradyne Corpor...

Страница 22: ...s may not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the u...

Страница 23: ...service marks of their respective owners Warranty Sales and Service Information Contact your local sales representative service representative or distributor directly for any help needed For addition...

Отзывы: