Firmware Download

The firmware download feature is available via the Ethernet port for future upgrades.
During a firmware download, the LED displays are:

H

ON:

ALM, ETHERNET, PWR, and TST

H

OFF:

DSL

Troubleshooting

LED Symptom

Action

All LEDs are on.

The RTU is not functional. Contact the NSP.

ALM LED remains
on.

The power-on self-test may have failed. Unplug the unit and
reapply power. If the alarm LED is still on, contact the NSP.

ALM and TST
LEDs remain on.

Refer to 

Firmware Download

.

 If the LEDs remain on after five

minutes, contact the NSP.

DSL LED is off.

Verify that the DSL cable is securely installed on both ends.

If the RTU is not in firmware download mode, unplug the RTU
and reapply power. If problem continues, contact the NSP

DSL LED continues
to blink after the
power-on self-test.

The RTU is attempting to establish the DSL link. If the DSL
LED continues to blink for more than five minutes, contact the
NSP.

DSL LED is on and
there is no data
transmission.

The DSL link has been established but there is no data
transmission. First, verify the Ethernet connection. If the
problem persists, contact the NSP.

DSL and Ethernet
LEDs are on and
there is no data
transmission.

The DSL link and the Ethernet link have been established. If
the problem continues, contact the NSP.

Ethernet LED is off.

Verify that:

H

The Ethernet 10BaseT cable is securely installed at both
ends, and

H

At least one PC is connected and powered on.

Verify that the correct straight-through or crossover cable is
installed. Refer to 

Cables & Connectors

,

 page 14.

Содержание HotWire 5246

Страница 1: ...ises Installation Instructions 5034 A2 GN10 HotWire 5034 Indoor POTS Splitter Customer Premises Installation Instructions Wiring and Cables Needed The following wiring and standard connectors are used...

Страница 2: ...ing is connected H From the demarcation point to the CP POTS splitter and H From the demarcation point to the DSL jack 97 15346 01 Punchdown Block or NID DSL Jack RTU New Wiring Connections Existing W...

Страница 3: ...hdown Block or NID DSL Jack RTU Customer Premises CP POTS DSL Ethernet Crossover Cable Ethernet Cable or Central Office CO Demarcation Point Local Loop HUB New Wiring Connections Existing Wiring POTS...

Страница 4: ...residential locations Procedure 1 Access the punchdown block or NID Disconnect the DSL access pair from the local loop WARNING Do not continue unless the DSL access line from the local loop has been...

Страница 5: ...ng POTS line and a second pair installed for DSL access The pair for the POTS line does not need to be disconnected unless a POTS splitter is going to be installed DSL POTS Access from Local Loop Tele...

Страница 6: ...that will be connected to the DSL jack Tighten both terminal screws with a flat blade screwdriver DSL POTS Access from Local Loop Wiring to DSL Jack Telephone Network Interface Device NID Ground Tip...

Страница 7: ...For pin assignments refer to Cables Connectors page 14 97 15343 01 DSL RJ11 Jack Central Office Punchdown Block or NID Customer Premises POTS DSL Local Loop Demarcation Point DSL Twisted pair Wiring...

Страница 8: ...e with clearance for the rear connectors Procedure 1 Use the RJ11 6 pin cable for the DSL connection Insert one end of the cable into the jack labeled DSL Insert the other end into the wall jack label...

Страница 9: ...or 97 15303 Ethernet Hub Ethernet Line POW ER ETHERNET D S L Ho tW ire RTU Ethernet Cable H Use an Ethernet crossover cable and connect the other end to a PC with an Ethernet Network Interface Card NI...

Страница 10: ...cable and snap the ferrite choke shut Press down on the plastic latch to secure the ferrite choke in place around the cable 5 Insert the power cord s round end into the jack labeled POWER Plug the tra...

Страница 11: ...the power on self test After a successful self test the LEDs should appear as indicated in BOLD in the Condition column below LED Condition Status PWR ON RTU has power ALM OFF ON No active alarms An a...

Страница 12: ...plug the RTU and reapply power If problem continues contact the NSP DSL LED continues to blink after the power on self test The RTU is attempting to establish the DSL link If the DSL LED continues to...

Страница 13: ...ly power watch all LEDs during the power on self test to verify that the PWR LED is functioning TST LED is on A test initiated by the NSP may be active Wait five minutes If the TST LED does not go off...

Страница 14: ...Cables Connectors Use standard twisted pair CAT3 or better cables This section is reference information H The DSL interface connector uses a 6 pin non keyed modular plug RJ11 6 Pin Connector Pin Funct...

Страница 15: ...D 2 10BaseT TX D 3 10BaseT RX D 4 5 Not used 6 10BaseT RX D 7 8 Not used To connect the RTU directly to a PC with an Ethernet NIC card use an Ethernet crossover cable 10BaseT TX D 10BaseT TX D 10BaseT...

Страница 16: ...handling Heat Dissipation 40 9 Btu hr max at nominal input voltage Interface Connectors DSL Interface Ethernet Type II Frame RJ11 6 pin 10BaseT 8 pin Technical Specifications subject to change withou...

Страница 17: ...nsformer with a Safety Extra Low Voltage SELV output having a maximum 240 VA available for use in the country of installation 9 In addition since the equipment is to be used with telecommunications ci...

Страница 18: ...1 200 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interfe...

Страница 19: ...e conditions may not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations ma...

Страница 20: ...repair installation documentation or training use one of the following methods H Via the Internet Visit the Paradyne World Wide Web site at http www paradyne com H Via Telephone Call our automated ca...

Отзывы: