![Paradyne FrameSaver SLV Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/paradyne/framesaver-slv-series/framesaver-slv-series_installation-instructions-manual_3611956009.webp)
9
Configuring the FrameSaver Unit
To configure the FrameSaver unit:
Set the system clock.
Assign the Node IP Address.
Set up Network physical interface, and DSX-1 physical interface, if applicable.
Enter time slot assignments, if applicable (FrameSaver 9124, 9126, or 9128 only).
Set up Data Port physical interface(s).
Set up modem call directories if dial-out traps are desired (FrameSaver 9126 or
9128 only).
Set up the ISDN DBM, if installed (FrameSaver 9126 or 9128 only).
Set up management.
Set up Auto-Configuration.
Enter trap managers.
Set up service provider connectivity.
NOTE:
Follow these instructions as they are presented. Installation time will be increased
if you connect the cables first.
Setting the System Clock
To set up the system clock:
1. Select Date & Time.
Main Menu
→
Control
→
Date & Time
2. Move the cursor to the first field and enter the:
– Date in mm/dd/yyyy format (month/day/year).
– Time in hh:mm format (hours:minutes).
3. Save the date and time, and return to the Main Menu.
Assigning the Node IP Address
1. Set up the node.
Main Menu
→
Configuration
→
Management and Communication
→
IP Node
2. Minimally, enter the following options:
– Node IP Address
– Node Subnet Mask
3. Save the configuration and return to the Configuration Edit/Display menu.