16
2. If the CSU/DSU will not be connected to a Paradyne DSLAM, change the DSLAM
Type. Other selections are Alcatel (NewBridge), PairGain, and Nokia.
3. Enter the Node IP Address and Node Subnet Mask.
4. Specify TS Access if a Troubleshooting (TS) DLCI or Virtual Circuit (VC) is being
set up for remote access by the service provider. The default is 0,35.
5. Select Create a Dedicated Network Management Link to set up for permanent
remote access by the NOC. Enter a DLCI, VPI, and VCI at the resulting prompts.
6. If Ethernet management will be used, select Ethernet Management Options Screen
to go directly to the Ethernet Management Options input screen.
—
Enable the interface (Status).
—
Respond Yes to the prompt
Would you like to set the Node's
Default IP Destination to Ethernet?
—
Enter the IP Address and Subnet Mask for the Ethernet interface.
—
Enter the Default Gateway Address (the IP Address that will be used for
packets without a specified route).
—
Enable Proxy ARP, or leave it disabled.
—
Press the Esc key to return to the Easy Install screen.
7. Change Network 1 DSL Line Rate (Kbps), if desired. The default is AutoRate.
If a Paradyne DSLAM is used, the default setting is AutoRate. For non-Paradyne
DSLAMs, the AutoRate setting is not valid and the default rate is 784 kbps.
8. Change Network 1 FRF.8 Encapsulation Mode, if desired. The default is
Transparent (data is forwarded without translation), which supports both frame relay
and ATM PVCs, and FrameSaver proprietary multiplexing.
9. Save the configuration.