4. AT Command Set and S-Registers
4-43
3830-A2-GB91-30
August 1998
Table 4-3
(14 of 20)
Model 3830 S-Registers
S65
Line Current Disconnect
Determines if the modem disconnects if an interruption in loop current
greater than 8 milliseconds or 90 milliseconds occurs.
Register has the following values:
0 = Enable (8 msec)
1 = Enable (90 msec)
2 = Disable
Factory setting is Enable (8msec).
S66
NMS Call Messages
Register determines if the modem sends information regarding status
(Call Progress) and/or sends summarized call statistics (Call Connect) to
the network management system (COMSPHERE 6700 Series NMS).
Register has the following values:
0 = Call Connect & Progress
1 = Disable
2 = Call Connect Only
3 = Call Progress Only
Factory setting is Call Connect & Progress.
S67
Directory Location 1 Callback
Determines if the modem uses the single number callback function.
Register has the following values:
0 = Disable
1 = Enable
Factory setting is Disable.
Содержание COMSPHERE 3830
Страница 1: ...COMSPHERE 3800 SERIES MODEMS MODEL 3830 USER S GUIDE Document No 3830 A2 GB91 30 August 1998 ...
Страница 6: ...COMSPHERE 3800 Series Modems Model 3830 E August 1998 3830 A2 GB91 30 Notices ...
Страница 22: ...COMSPHERE 3800 Series Modems Model 3830 1 6 August 1998 3830 A2 GB91 30 ...
Страница 86: ...COMSPHERE 3800 Series Modems Model 3830 4 50 August 1998 3830 A2 GB91 30 ...
Страница 104: ...COMSPHERE 3800 Series Modems Model 3830 C 6 August 1998 3830 A2 GB91 30 ...
Страница 114: ...COMSPHERE 3800 Series Modems Model 3830 D 10 August 1998 3830 A2 GB91 30 ...
Страница 126: ...COMSPHERE 3800 Series Modems Model 3830 Glossary 12 August 1998 3830 A2 GB91 30 ...