AT Commands and S-Registers
4-31
3825-A2-GB30-20
November 1996
Table 4-3
(3 of 3)
3825
Plus Security Commands
S97
DTE Password Termination Character
Determines ASCII value used to indicate the end of a password or Callback Directory/Number entered by the remote
user.
Enter a value from 0–127 for the command end character.
The factory setting is 13 (ASCII carriage return).
S98
DTE Password Backspace Character
Determines ASCII value used as the backspace (Backspace key) when entering a password or Callback
Directory/Number. This character moves the cursor to the left and erases the previous character.
Enter a value from 0–127.
The factory setting is 08 (ASCII backspace).