4
Model 3810 Dial Connection
For the Model 3810, use the following procedures to connect the modem to the dial
network interface:
1. Insert the 6-position, 4-conductor modular plug into the jack labeled DIAL / LEASED
(3820).
2. Insert the other end of the modular cord into the network interface.
Model 3810 Leased Line Connection
Use the following procedures to connect a Model 3810 to the 2-wire or 4-wire
leased-line network interface:
1. Insert the 8-position, 8-conductor modular plug into the jack labeled
PHONE / LEASED (3810).
2. Insert the other end of the modular cord into the leased-line network interface.
PHONE
DIAL
NMS
DTE
PWR
0
1
LEASED
(3820)
LEASED
(3810)
98-13070-02
8-POSITION,
8-CONDUCTOR PLUG
FOR LEASED LINE
NETWORK OPERATION
(CONNECTS WITH
JM8 TYPE JACK)
6-POSITION,
4-CONDUCTOR PLUG
FOR TELEPHONE SET
6-POSITION, 4-CONDUCTOR PLUG FOR
PERMISSIVE DIAL NETWORK OPERATION
(CONNECTS WITH RJ11C TYPE JACK)