COMSPHERE

 3600 SERIES

DATA SERVICE UNITS

TIME DIVISION MULTIPLEXER,

MULTICHANNEL MULTIPOINT,

AND DIGITAL BRIDGE OPTIONS

QUICK REFERENCE

Document No. 3610-A2-GL12-00

Содержание COMSPHERE 3610

Страница 1: ...COMSPHERE 3600 SERIES DATA SERVICE UNITS TIME DIVISION MULTIPLEXER MULTICHANNEL MULTIPOINT AND DIGITAL BRIDGE OPTIONS QUICK REFERENCE Document No 3610 A2 GL12 00...

Страница 2: ...and issued as a new release to this manual Warranty Sales and Service Information Contact your local sales representative service representative or distributor directly for any help needed For additio...

Страница 3: ...oint and Digital Bridge Options Supplement To request a paper copy of a Paradyne document Within the U S A call 1 800 PARADYNE 1 800 727 2396 Outside the U S A call 1 727 530 8623 Things to Know Befor...

Страница 4: ...en your firmware version is 6 33 or greater each port can be set individually for either EIA 232 or V 35 using the front panel an async terminal or an NMS Based on your model you may need to perform o...

Страница 5: ...l connectors 496 14706 02 Snap Tabs R UL R THIS DIGITAL APPARATUS DOES NOT EXCEED THE CLASS A LIMITS FOR RADIO NOISE EMISSIONS FROM DIGITAL APPARATUS SET OUT IN THE RADIO INTERFERENCE REGUAALTIONS OF...

Страница 6: ...rd the front panel Do not allow any cables to pull free from the inside front panel connectors 496 14707 01 With TDM or MCMP Snap Tabs COMSPHERE 36 10 2 Disconnect the LCD flat cable by working the ca...

Страница 7: ...5 LCD Flat Cable Keypad Flat Cable DSU Circuit Card Expanded Base Snap Tabs TDM or MCMP Flat Cable Screw 98 13846d Snap Tabs Screw Screw Assembling and Disassembling a TDM or MCMP DSU...

Страница 8: ...2 Disconnect the LCD flat cable by working the cable free of the connector 3 Disconnect the TDM or MCMP flat cable 4 Unscrew the three screws holding the DSU circuit card in place 5 Lift the DSU circ...

Страница 9: ...front panel an async terminal or an NMS The firmware version must be 6 33 or greater Adding a MUX CCA To upgrade a 3610 DSU with a MUX CCA Procedure 1 Fold the TDM Flex or TDM Flex flat cable over th...

Страница 10: ...ont corners and the 4 screw with the captive lock washer at the back corner 2 Connect the flat cable s 40 position header to the DSU as shown on page 5 3 Connect the keypad flat cable by inserting the...

Страница 11: ...P CC DC EIA 232 V 35 CAUTION Only use the power transformer designed for the Model 3610 DSU Using other transformers may result in personal injury or damage to the equipment 2 Connect the 3 prong plug...

Страница 12: ...peed higher than 19 2 kbps it is recommended that the port interface be set to V 35 An interconnect cable is required for every port 2 through 6 that is set to V 35 interface Reconfiguring Ports If yo...

Страница 13: ...7 Press the function key directly below MUX The Change MUX Opts screen appears F1 Change MUX Opts Copy Setup Prt1 F2 F3 Prt2 Prt3 Prt4 Prt5 Prt6 8 Select a port Any of the installed ports Prt1 throug...

Страница 14: ...n originate a Digital Test in a point to point or multipoint network Use Position in the Diagnostic General configuration option table to set a unit to Cntrl A tributary DSU can originate a Digital Te...

Страница 15: ...menus appear and the selections available within the menus Use the MUX Function configuration option to set the mode of operation Access to all network management tasks from the front panel begins at...

Страница 16: ...p Test Ctrl Msgs Address Confg Stat H S DTE CircQ ID TPwr Port Select Devic Expan Subn Backup Branch The Backup Bckup branch controls operation of digital bridging when a DSU with TDM or MCMP has MUX...

Страница 17: ...L DTE DL RL Start Start Start Port Select Port Select Port Select Port Select Address Address Address Run Tim Blocks Displ Clr EE DT BERT Port Select Subn Selective DTone Configuration Branch The Conf...

Страница 18: ...sr1 Usr2 Usr3 FacC FacT FacB Load SAVE DSU DBM Gen Bkup MUX PrtSp LPDA Copy Setup Prt1 Prt2 Prt3 Prt4 Prt5 Prt6 Remt Usr1 Usr2 Usr3 Address Activ Usr1 Usr2 Usr3 TDM MCMP CBrdg EBrdg None DSU DBM Chan...

Страница 19: ...56 kbps Ports 3 6 are not available for 2 port Flex MUX models z Not available for a DBM X or a DSU with Primary core set to Yes the DSU is Disabled zz 4 wire Switched 56 DBM only Appears with MCMP TD...

Страница 20: ...RTS Cntrl FrcOn DTE CTS Cntrl Std RTS LSD Lead A Std Delay FrcOn CTS Lead A Std Delay FrcOn SystemStat A Enab Disab Circ Assur A Enab Disab Tst Pattern A AT T Std RespondRDL A Enab Disab LL by DTE A E...

Страница 21: ...Disab RxElasStor A Enab Disab Call Setup None Pswrd Clbk Alarm RxPwd 10 characters TxPwd 10 characters V 13 Signl Enab Disab Dial Test A Enab Disab Primary Core A Yes No DtrCallCon Orig z Ansr Disab E...

Страница 22: ...speed Disab Prt1 Prt2 Prt3 Prt4 Prt5 Prt6 DBM Fallback1 PrtSp Configuration Options Value Prtn SS S LD 48 38 4 32 28 8 19 2 18 0 16 8 14 4 12 0 9 6 8 4 7 2 4 8 4 0 2 4 2 0 1 2 Disab Underspeed Disab P...

Страница 23: ...1 100 sec async terminal 0 100 DSR FrcOn A Enab Disab DSR on Tst A Enab Disab Extend Chan A Yes No Upstrm Port A Prt1 Prt2 Prt3 Prt4 Prt5 Prt6 DTE Port EIA232 V 35 DCE Type Analg Digtl DSU MCMP PrtSp...

Страница 24: ...64 installed Fallback One MUX Setup Configuration Options Value MUX Funct TDM MCMPa CBrdg EBrdg None Share DevA Enab Disab Lowest Port 1 2 3 4 5 Ports in Gp 2 3 4 5 6 Port Cntrl Host DSD Share DevB En...

Страница 25: ...DTE TxCarrSel A Const Cntrl RxCarrSel A Const Cntrl Mark PCC Buffer Enab Disab Elast Stor A Enab Disab RTS CTS Del A 0 1040 ms 8 ms increments DTR Alarm A Enab Disab AntiStream A Disab 1 100 sec asyn...

Страница 26: ...Port DCE 2 3 4 5 Ports in Gp 2 3 4 5 6 Port Cntrl Host DSD Share DevB Disab Prtn Configuration Options Value RTS Cntrl FrcOn DTE TxCarrSel A Const Cntrl RxCarrSel A Const Cntrl Mark PCC Buffer Enab Di...

Страница 27: ...tatus of the general purpose external DTE leads 496 12974 02 TOP LEVEL MENU Local Remot Bckup Test Stat Msgs Address Confg Ctrl TxCtl LEDs ExtL DSU DBM Ports Load Save Displ Chang Enab Disab Devic Por...