![Paradyne Comsphere 3511 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/paradyne/comsphere-3511/comsphere-3511_user-manual_753895025.webp)
Operation
3-3
3510-A2-GN32-70
July 1999
Table 3-1
(2 of 3)
3500 Series Indicators and Switches
Name
Function
Definition
PASS
Pass
This green indicator lights if the DSU has
completed a device test without a failure. The
indicator remains on until another key is
pressed.
FAIL/STR/DSBL
(3510)
Dsbl/Fail (3511)
Failure/Error/Streaming/Disable
This red indicator performs four functions:
FAIL/Dsbl (3510/3511) – Indicator lights at
the end of a Device Test if the test was not
successful. The indicator remains ON until
another key is pressed.
Fail (3511) – This indicator rapid flashes
during Test Pattern when errors are detected.
DSBL (3510) – Indicator lights if the DSU has
been disabled.
STR (3510) – Indicator slow flashes when a
streaming terminal alarm condition exists.
( NOTE: The RTS indicator will also be ON.)
TP
Test Pattern
This yellow indicator lights when the test pattern
generator/comparator circuit is active. Press the
TP pushbutton switch to generate a local test
pattern.
LL
Local Loopback
This yellow indicator lights when the DSU is in
local loopback. Press the LL pushbutton switch
to initiate a local loopback test.
DL
Digital Loopback
This yellow indicator lights when the DSU is
performing a digital loopback or a channel
loopback. Press the DL pushbutton switch to
initiate a local digital or channel loopback test.
RL
Remote Loopback
This yellow indicator lights when a remote digital
loopback has been requested of the remote
DSU. Press the RL pushbutton switch to initiate
a digital loopback test at the remote end.
TXD (103)
2
Transmit Data
This green indicator is steady-ON when MARKS
are transmitted, goes Off when spaces are
transmitted, and flashes at a steady rate when
variable data are transmitted.
RXD (104)
2
Receive Data
This green indicator is steady-ON when marks
are being received, goes Off when spaces are
received, and blinks at a steady rate when
variable data are received.
2
ITU-T designation.
Содержание Comsphere 3511
Страница 4: ...COMSPHERE 3500 Series Data Service Units C July 1999 3510 A2 GN32 70 Notices ...
Страница 6: ...COMSPHERE 3500 Series Data Service Units E July 1999 3510 A2 GN32 70 ...
Страница 12: ...COMSPHERE 3500 Series Data Service Units vi July 1999 3510 A2 GN32 70 ...
Страница 37: ...Operation 3 15 3510 A2 GN32 70 July 1999 Figure 3 8 Out of Service Condition Troubleshooting Flowchart ...
Страница 39: ...Operation 3 17 3510 A2 GN32 70 July 1999 Figure 3 10 Streaming Terminal Condition Troubleshooting Flowchart ...
Страница 54: ...COMSPHERE 3500 Series Data Service Units 4 14 July 1999 3510 A2 GN32 70 Figure 4 8 DSU Strap Default Settings ...
Страница 72: ...COMSPHERE 3500 Series Data Service Units A 6 July 1999 3510 A2 GN32 70 ...
Страница 74: ...COMSPHERE 3500 Series Data Service Units B 2 July 1999 3510 A2 GN32 70 Figure B 1 DSU Timing Chart 1 of 2 ...
Страница 75: ...Timing During Testing B 3 3510 A2 GN32 70 July 1999 Figure B 1 DSU Timing Chart 2 of 2 ...
Страница 76: ...COMSPHERE 3500 Series Data Service Units B 4 July 1999 3510 A2 GN32 70 ...