8. When installed in the final configuration, the product must comply with the

applicable Safety Standards and regulatory requirements of the country in which it
is installed. If necessary, consult with the appropriate regulatory agencies and
inspection authorities to ensure compliance.

9. A rare phenomenon can create a voltage potential between the earth grounds of

two or more buildings. If products installed in separate buildings are
interconnected, the voltage potential may cause a hazardous condition. Consult a
qualified electrical consultant to determine whether or not this phenomenon exists
and, if necessary, implement corrective action prior to interconnecting the products.

10. Filler panels are provided with the access carrier to cover unused slots. You 

must

install filler panels on the unused slots to avoid possible injury from electrical shock
and to maintain compliance with FCC rules.

11. In addition, if the equipment is to be used with telecommunications circuits, take

the following precautions:

— Never install telephone wiring during a lightning storm.

— Never install telephone jacks in wet locations unless the jack is specifically

designed for wet locations.

— Never touch uninsulated telephone wires or terminals unless the telephone

line has been disconnected at the network interface.

— Use caution when installing or modifying telephone lines.

— Avoid using a telephone (other than a cordless type) during an electrical

storm. There may be a remote risk of electric shock from lightning.

— Do not use the telephone to report a gas leak in the vicinity of the leak.

12. To reduce the risk of fire, this component card cage must be installed in a suitable

Electrical and Fire Enclosure that complies with enclosure, mounting, casualty and
segregation requirements of the end-use product. Openings located within the
enclosure must be separated from any network-connected component by a
minimum of 25 millimeters of air when measured in any dimension, unless the
openings are 5 millimeters or less, or measure one millimeter in length, regardless
of the width.

Содержание 9000 Series

Страница 1: ...ccess carrier verify that your package also contains the following Power supply already installed and power cord Fan tray for NAMs already installed Baffle for heat deflection including extender brackets for installation in a 23 inch rack and associated screws Alarm Relay Connector COM Port to PC cable Set of five filler panels with screws for any unused NAM slots and I O slots Two panels that cov...

Страница 2: ...as a disconnect device and overcurrent protection A clean well lit and ventilated site that is free from environmental extremes One to two feet of clearance for cable connections Strain relief material for cable support A large Phillips screwdriver to install the access carrier in a cabinet or rack A small or medium Phillips screwdriver to install the I O card filler panels and front filler panels...

Страница 3: ...IA 310 C standard Follow these rules during installation H Install access carriers from the bottom of the cabinet and work up This provides the following Proper alignment for subsequent access carriers Easier installation since the access carriers can be lowered onto the mounting screws from above Convenient connection of the interface cables Proper cabinet balance Bottom up installation keeps the...

Страница 4: ...ng Bracket 496 15131 Front of 19 Inch Carrier Cabinet 9th Hole Keyhole 2 Place the access carrier against the front rail of the cabinet allowing the installed machine screws on each side to pass through the keyholes 3 Lower the access carrier into place allowing the keyholes to slide under the screw heads This positions and supports the access carrier correctly for installation of the remaining ma...

Страница 5: ...ws to pass through the keyholes Front Rail Mounting Bracket 496 15132 Front of 19 Inch Carrier Cabinet 9th Hole Speed Nut Screw 3 Install the remaining machine screws at the top and bottom on both sides of the brackets then tighten them Power Supply The DC power supply is designed and approved for 48 VDC power systems The access carrier obtains low voltage power from the power supply H The power s...

Страница 6: ... redundant power supplies After making any necessary connections to your alarm system plug the connector that you received in the box with the housing into the socket on the power I O card 99 16458 Rear View with Power I O Card THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIREMENT S OF THE CANADIAN INTERFERENCE CAUSING EQUIPMENT REGULATIONS CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTES LES ...

Страница 7: ...talling the baffle in a 23 inch rack attach the two extender brackets to each side of the baffle using four of the Speed Nuts 12 24 and four of the screws 12 24 x 1 2 inch provided 2 If the rack does not have threaded screw holes slip a Speed Nut onto the first available hole on each side of the rack beneath the installed carrier Align the hole of the Speed Nuts with the hole in the rails 3 Using ...

Страница 8: ...n information 99 16453 Rear View Screws THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIREMENT S OF THE CANADIAN INTERFERENCE CAUSING EQUIPMENT REGULATIONS CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTES LES EXIGENCES DU REGLEMENT SUR LE MATÉRIAL BROUILLER DU CANADA THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAU...

Страница 9: ...lect the proper filler panel size to cover empty slots 2 At the rear of the carrier align the filler panel with the upper and lower tracks of the slot then screw the panel into place using the screws provided NAM Card Installation A NAM is required for network access and acts as an interface between the network and the customer premises equipment NAMs are installed from the front of the access car...

Страница 10: ... into the panel using the captive screw already installed 4 Screw the top ejector into the panel using the extra captive screw provided Fully Loaded Access Carrier 99 16455 Rear View Slot 14 THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIREMENT S OF THE CANADIAN INTERFERENCE CAUSING EQUIPMENT REGULATIONS CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTES LES EXIGENCES DU REGLEMENT SUR LE MATÉRIA...

Страница 11: ...ES DU REGLEMENT SUR LE MATÉRIAL BROUILLER DU CANADA THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION ALARM RELAYS COM NO NC COM NO NC 48V 24V RETURN 48V 24V RETURN A B SYSTEM POWER F...

Страница 12: ...pts 14 AWG or 18 AWG wire The section labeled A is for the primary power supply The section labeled B is for the redundant power supply 4 Connect the grounded positive lead of the voltage source or battery to the terminal labeled RETURN in either the A or B section 5 Connect the negative 48 VDC lead wire to the terminal labeled 48V in either the A or B section 6 Secure power cables to the cable ti...

Страница 13: ...t protection must be a 15 or 20A 48 VDC fuse or circuit breaker This product is to be installed only in a Restricted Access Location dedicated equipment rooms equipment closets or the like in accordance with articles 110 16 110 17 and 110 18 of the National Electrical Code ANSI NFPA 70 and articles 2 308 2 310 2 312 2 314 2 200 and 2 202 of the Canadian Electrical Code The rear I O panel has provi...

Страница 14: ...pment is to be used with telecommunications circuits take the following precautions Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Use caution when installing ...

Страница 15: ...residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne In order to maintain compliance with FCC limits any suppli...

Страница 16: ... a company representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about this document Please mail them to Technical Publications Paradyne Corporation 8545 126th Ave N Largo FL 33773 or send e mail to userdoc paradyne com Include the number and title of this document in your correspondence Please include y...