background image

 8

7112-A2-GN10-40

February 2000

Table 3.

Network Interface Options

Configuration Option

Settings (default in Bold)

Primary Clock Source

Network, Internal, Port

Line Framing Format

ESF, D4

Line Coding Format

B8ZS, AMI

Bit Stuffing

62411, Part68, Disable

Line Build Out (LBO)

0.0, –7.5, –15, –22.5

FDL Management Link

Enable, Disable

FDL IP Address

000.000.000.000 – 255.255.255.255, clear

FDL Subnet Mask

000.000.000.000 – 255.255.255.255

Network Initiated Line Loopback (LLB)

Enable, Disable

Network Initiated Payload Loopback
(PLB)

Enable, Disable

ANSI Performance Report Messages

Disable, Enable

Circuit Identifier

< Blank >

Table 4.

Cross Connect Assignments

Configuration Option

Settings (default in Bold)

Assign By

Block, ACAMI, Channel

Synchronous Data Port Assignments

P(B)

The default is all DS0s assigned to the
data port

...

data port.

P(B)

Table 5.

Data Port Options

Configuration Option

Settings (default in Bold)

Port Base Rate

Nx64, Nx56

Invert Transmit Clock

Enable, Disable

Transmit Clock Source

Internal, External

Invert Transmit and Received Data

Enable, Disable

Send All Ones on Data Port Not Ready

Disable, DTR, RTS, Both

Action on Network Yellow Alarm

None, Halt

Network Init. Data Channel Loopback

Disable, V.54, FT1, Both

Port (DTE) Initiated Loopbacks

Disable, DTLB, DCLB, Both

Содержание 7112

Страница 1: ...n for this product is available at www paradyne com Select Library Technical Manuals Subrate Digital Access Devices Select the following document 7112 A2 GB20 Model 7112 T1 DSU CSU with Internal Ether...

Страница 2: ...other end A DCE with a V 35 connector to the DTE port Standard V 35 crossover cable with MS34 plug connectors on both ends Contact your sales or service representative to order these cables For cable...

Страница 3: ...e DSU CSU 1 Plug the 8 pin connector on the RJ48C network cable into the NETWORK connector on the DSU CSU 2 Plug the other end of the RJ48C network cable into the RJ48C modular jack 3 Plug one end of...

Страница 4: ...l or PC 1 Use a standard serial crossover cable as shown in Figure 1 on the next page 2 Enable auto answer on your modem and configure it to use standard RS 232 detection and control for LSD DSR and D...

Страница 5: ...Pin 13 Pin 25 P2 Plug Chassis Ground TXD RXD RTS CTS DSR Signal Ground CD RLSD TXC RXC DTR XTXC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Pin 98 15811 1 2 3 4 5 6 7 8 9 10 11 1...

Страница 6: ...is displayed on the ASCII terminal or PC Press the Enter key Verify that the Main Menu appears main Access Level 1 PARADYNE Device Name Model 7112 MAIN MENU Status Test Configuration Control Ctrl a t...

Страница 7: ...ing Determine if you want SNMP traps generated Refer to Chapter 8 Messages and Troubleshooting Change configuration option settings Refer to Appendix A Configuration Option Tables and Appendix B Works...

Страница 8: ...e ANSI Performance Report Messages Disable Enable Circuit Identifier Blank Table 4 Cross Connect Assignments Configuration Option Settings default in Bold Assign By Block ACAMI Channel Synchronous Dat...

Страница 9: ...gs default in Bold Data Rate Kbps 2 4 4 8 9 6 14 4 19 2 28 8 38 4 Character Length 7 8 Parity None Even Odd Stop Bits 1 2 Monitor DTR Enable Disable Login Required Enable Disable Port Access Level Lev...

Страница 10: ...Security NMS IP Validation Enable Disable Number of Managers 1 2 3 4 5 6 7 8 9 10 NMS n IP Address 000 000 000 000 255 255 255 255 Access Level Read Read Write SNMP Traps SNMP Traps Enable Disable Nu...

Страница 11: ...ulatory agencies and inspection authorities to ensure compliance 7 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate...

Страница 12: ...rence to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own e...

Страница 13: ...CC compliant telephone cord and modular plug is provided with this equipment This equipment is designed to be connected to the telephone network or premises wiring using a compatible jack which is Par...

Страница 14: ...c water pipe system if present are connected together This precaution may be particularly important in rural areas CAUTION Users should not attempt to make such connections themselves but should conta...