2. Installation
3160-A2-GB24-10
March 2001
2-7
Installing the Single –48 Vdc Power Supply
To install the Model 3164 DSU/CSU using a single source –48 Vdc SELV power
supply, refer to
Figure 2-9, –48 Vdc Single Source Power Supply Pinouts
, and use
the following procedure.
Procedure
To install the –48 Vdc single source power supply:
1. Connect the black and red wires to the –48 Vdc return source.
2. Connect the green wire to a suitable ground.
3. Connect the orange and blue wires to the –48 Vdc input source.
4. Cut the white wire off at the outer insulation.
5. Plug the power connector into the DSU/CSU.
Figure 2-9.
–48 Vdc Single Source Power Supply Pinouts
1
2
3
4
5
6
BLACK
RED
GREEN
WHITE
ORANGE
BLUE
– 48 VDC INPUT
99-14299-02
X
GROUND
DSU/CSU POWER
PLUG
TO CUSTOMER-SUPPLIED BATTERY
– 48 VDC RETURN
Содержание 3165
Страница 14: ...Contents viii March 2001 3160 A2 GB24 10 ...
Страница 18: ...About This Guide xii March 2001 3160 A2 GB24 10 ...
Страница 26: ...1 Introduction 1 8 March 2001 3160 A2 GB24 10 ...
Страница 38: ...2 Installation 2 12 March 2001 3160 A2 GB24 10 ...
Страница 54: ...3 Using the Front Panel 3 16 March 2001 3160 A2 GB24 10 ...
Страница 102: ...4 Configuration 4 48 March 2001 3160 A2 GB24 10 ...
Страница 110: ...5 Security 5 8 March 2001 3160 A2 GB24 10 ...
Страница 162: ...8 Testing 8 24 March 2001 3160 A2 GB24 10 ...
Страница 164: ...A Front Panel Menu A 2 March 2001 3160 A2 GB24 10 ...
Страница 222: ...D Configuration Worksheets D 14 March 2001 3160 A2 GB24 10 ...
Страница 240: ...E Pin Assignments E 18 March 2001 3160 A2 GB24 10 ...
Страница 272: ...F SNMP MIB Objects F 32 March 2001 3160 A2 GB24 10 ...
Страница 280: ...G IP Network Addressing Scenarios G 8 March 2001 3160 A2 GB24 10 ...
Страница 300: ...J Equipment List J 2 March 2001 3160 A2 GB24 10 ...