Configuration Options
C-10
3162-A2-GB20-40
August 2000
Table C-3.
Sync Data Port Configuration Options (5 of 5)
Excessive Error Rate Threshold: 10E-4
10E-4 10E-5 10E-6 10E-7 10E-8 10E-9
Sets the error rate threshold that determines when an Excessive Error Rate (EER)
condition is declared for a particular port. The error rate selected by this configuration
option is determined by the ratio of the number of CRC5 errors to the total number of
bits received over a set period of time.
10E-4 – 10E-4 Threshold. For example, at 1536 kbps, EER is declared if more than
1,535 CRC5 errors are detected in a 10-second period. It is cleared with less than
1,536 errors in ten seconds.
10E-5 – 10E-5 Threshold. For example, at 1536 kbps, EER is declared if more than
921 CRC5 errors are detected in a 60-second period. It is cleared with less than
922 errors in sixty seconds.
10E-6 – 10E-6 Threshold. For example, at 1536 kbps, EER is declared if more than
92 CRC5 errors are detected in a 60-second period.
It is cleared with less than 93 errors
in sixty seconds.
10E-7 – 10E-7 Threshold. For example, at 1536 kbps, EER is declared if more than
9 CRC5 errors are detected in a 60-second period. It is cleared with less than 10 errors
in sixty seconds.
10E-8 – 10E-8 Threshold. For example, at 1536 kbps, EER is declared if more than
41 CRC5 errors are detected in three 15-minute intervals. It is cleared with less than
42 errors in three 15-minute intervals.
10E-9 – 10E-9 Threshold. For example, at 1536 kbps, EER is declared if more than
4 CRC5 errors are detected in three 15-minute intervals. It is cleared with less than
5 errors in three 15-minute intervals.
NOTE:
This configuration option is not available if EDL is disabled.
Содержание 3162
Страница 1: ...ACCULINK 3162 DSU CSU USER S GUIDE Document No 3162 A2 GB20 40 August 2000 ...
Страница 12: ...Contents vi 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Страница 16: ...About This Guide x 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Страница 42: ...Operation 3 16 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Страница 64: ...Configuration 4 22 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Страница 94: ...Monitoring and Testing 5 30 3162 A2 GB20 40 August 2000 This page intentionally left blank ...
Страница 186: ...Equipment List G 2 3162 A2 GB20 40 August 2000 This page intentionally left blank ...