10
Table 2. DTE Interface Configuration Options
Option
Factory 1
Factory 2
Comments/Description
Interface Status:
Enable
Enable
Enables the use of the DTE
Interface Status:
Disable
Disable
Enables the use of the DTE
Drop/Insert port.
Line Framing
D4
D4
Selects D4 or ESF framing format
Line Framing
Format:
ESF
ESF
Selects D4 or ESF framing format.
Line Coding Format:
AMI
AMI
Selects AMI or B8ZS line coding
Line Coding Format:
B8ZS
B8ZS
Selects AMI or B8ZS line coding
format.
0–133
0–133
133–266
133–266
Line Equalization:
266–399
266–399
Provides selectable extended DTE
range capability.
399–533
399–533
range capability.
533–655
533–655
DTE LB on External
C
t
t
Enable
Enable
Allows control of DLB on external
Contact:
Disable
Disable
Allows control of DLB on external
contact closure.
Send All Ones on
Enable
Enable
Sends all ones on channels
ll
t d t th
t
k T1
Send All Ones on
DTE Failure:
Disable
Disable
allocated to the network T1 on
LOS, LOF, or AIS.
Line 1 Displays:
Line 2 Displays:
Meaning
Comments/Description
DTE Signaling
D01 D02
D24
RBS
Voice
Channel
Specifies which channels from the
DTE Drop/Insert interface are
voice channels and should pass
D01 D02... D24:
None
Data Channel
voice channels and should pass
RBS information to the network.
All manuals and user guides at all-guides.com