Wiring
LED Feedback
Test Mode
To facilitate installation and verify correct wiring, the ZX16D features five Test Modes. In order to use this feature, the
ZX16D module must be powered (Test Mode 1 requires a full bus connection).
To enter Test Mode, press the LOC button. The ZX16D enters Test Mode 1. Press the LOC button again to enter Test Mode
2, and so on. On the sixth press, the ZX16D will exit Test Mode.
1
I
NPUT
D
EVICES
For input device wiring options, see ??
2
E
XTERNAL
M
ODULE
T
AMPER
S
WITCH
Input 16 (N.C.) only.
ZX16D
INPUT
1
2
3
4
C
C
INPUT
5
6
7
8
9
C
C
INPUT
10 11 12
13 14 15 16
C
C
BUS INPUT
Detection Device
N.O. N.C. C
+
_
Imperial Multibus
1
2
ZX16D
INPUT
1
2
3
4
C
C
INPUT
5
6
7
8
9
C
C
INPUT
10 11 12
13 14 15 16
C
C
BUS INPUT
BUS
RX
TX
STATUS
Green Green
flash
Green
flash
OK (communication in
progress)
Red
on
-
-
Short on GRN or YEL
-
Green
on
Communication failure/
too many modules
Green
on
Green
on
Bus lines reversed (GRN
/ YEL)
Red
flash
-
-
Bus power too low
Green
flash
Green
flash
Module locate mode
Blue
flash
-
-
Firmware upgrade in
progress
Input Status LEDs
Off = Input/zone closed
Red on = Input/zone open
Red flash = zone tamper
Mode
Feature
LED
Feedback
Instructions
Mode 1* Input assignment RX flashes x 1 Entering Mode 1 illuminates all zones that have already been assigned in the control
panel.*This feature will be available on future versions.
Mode 2 EOL disabled
Tamper disabled
RX flashes x 2 Entering Mode 2 sets the ZX16D for:
No EOL / No tamper
. To verify correct EOL /
tamper wiring, open and close the zone and verify that the zone’s LED reacts
accordingly.
Mode 3 EOL enabled
Tamper disabled
RX flashes x 3 Entering Mode 3 sets the ZX16D for:
With EOL / No tamper
. To verify correct EOL /
tamper wiring, open and close the zone and verify that the zone’s LED reacts
accordingly.
Mode 4 EOL enabled
Tamper enabled
RX flashes x 4 Entering Mode 4 sets the ZX16D for:
With EOL / With tamper
. To verify correct EOL /
tamper wiring, open and close the zone and verify that the zone’s LED reacts
accordingly.
Mode 5 Zone test
RX flashes x 5 Entering Mode 5 illuminates all connected zones. When a zone is triggered, the
corresponding zone LED will turn off, indicating correct wiring.