SR250-EI00 01/2021

PARADOX.COM

Programming

Program the SR250 either though a supported keypad or through 
BabyWare software (BabyWare). 

Programming with Keypads

Programming with BabyWare

1.

Open BabyWare > Connect your Account.

2.

In the Main window: Select the 

Add Item

 button > 

Wireless Sirens

.

3.

Fill-in the SR250 label, location and serial number.

4.

Select 

Save.

Upgrading Firmware

Upgrade SR250 firmware through the Paradox InField software (V5.5.9 or 
higher) using the 307USB Direct Connect Interface. The SR250 requires the 
batteries installed in order to upgrade the firmware.

Note:  

Ensure that the SR250 is awake before upgrading the firmware. 

To wake up the siren

: press the Learn switch (see #9 in 

Figure 1

). The 

siren provides a 60 second delay in order to begin the update.

1.

Remove the front cover as well as the PCB cover.

2.

Connect the 307USB to the InField connector (see #4 in 

Figure 1

).

3.

Upgrade according to the firmware upgrade instructions: Go to 
www.paradox.com > Software > InField Firmware Upgrade 
Instructions.

Tamper Supervision

If a tamper is detected, the SR250 will sound an alarm and the strobe light 
will flash for 4 minutes. The control panel will follow the global supervision 
options set in the panel.

Specifications

Warranty

For complete warranty information on this product, please refer to 
the Limited Warranty Statement found on the Statement. Your use of 
the Paradox product signifies your acceptance of all warranty terms 
and conditions. Please ensure that your use of the Paradox product is 
in compliance with local, national, and international laws.

© 2021 Paradox Security Systems (Bahamas) Ltd. All rights reserved. 
Specifications may change without prior notice. US, Canadian and 
international patents may apply. BabyWare and Paradox 
are a trademarks or registered trademarks of Paradox 
Security Systems (Bahamas) Ltd. or its affiliates in 
Canada, the United States and/or other countries.

Feature

Program

MG6250

MG/SP

EVO192/HD

(requires RTX3)

Sections correspond to sirens 1- 4.
EXAMPLE: [0802]: Learn Siren 2 for 
MG6250

Sections 
correspond to 
sirens 1 - 8

Learn Siren

[0801] - [0804]

[683] 

[686]

[2851] 

-

 [2858]

Press and hold the 

Learn

 switch for 3 seconds after 

entering the section to learn the siren. 

WARNING

: When pressing the Learn switch, the 

SR250 squawks and the strobe light flashes five 
times to confirm siren registration to the panel

Assign Partition 
to Siren

-

-

[2861] 

[2868]

Display Signal 
Strength

[0801] 

[0804]

[687] 

[690]

[2871] 

-

 [2878]

Press and hold the 

Learn

 switch for 3 seconds after 

entering the section to display the siren signal 
strength that the panel receives. Requires keypad 
V1.3 or higher

Label Siren

[0811] 

[0814]

[691] 

[694]

-

Labels identify sirens when reporting events (for 
MG/SP only: via e-mail through the IP150+. 
For MG6250 through SMS personal reporting) 
and for troubleshooting purposes. Maximum 16 
characters

Temporary 
Tamper Switch 
Deactivation for 
Maintenance

[0800]

[695]

[2870]

Press 

[ENTER] 

after entering the section to 

deactivate tamper alarm until the cover is 
reinstalled or after 30 minutes

Panel 
Supervision of 
Siren

[0820]

[587]

-

ON

: Enabled (default)

OFF

: Disabled

The control panel supervises the presence of the 
SR250. If lost, the control panel follows global 
supervision options set in the control panel

Specification

Description

Power

4.5 Vdc (3 “D” size alkaline batteries) 
Optional: 8-16 Vac / 9-20 Vdc external power

Battery life

Up to 3 years based on normal use (e.g., 2 alarms 
per year with strobe for 2.5 hours and 8 squawks 
per day at an average of 25 ºC (77 ºF). Using 
optional power source will extend battery life

Low Battery 
Voltage Signal

Signal sent at 3.4 Vdc

Consumption

Sleep: 22 uA, Standby: 130 uA, Alarm: 550 mA

RF frequency

433 MHz or 868 MHz

Siren

100 dB (1 meter)

For EN, maximum sound duration should be set to 
4 minutes

Siren Type

Type X / Type W

Dimensions

24 x 6 x 18 cm (9.5 x 2.3 x 7 in.)

Operating 
Temperature

Battery only: -30 ºC to 50 ºC (-22 ºF to 122 ºF) 

RF range

70m (229 ft)

Certification

EN 50131-4, EN 50131-1 Grade 2, EN 50130-5 
Environmental Class IV, CE
IP Rating: IP54
Certification Body: Applica Test and Certification

Please use only safety approved power supply according to IEC/EN 60950-1 
or 62368-1 with rated voltage of 8-16 Vac or 9-20 Vdc and rated current of 

2A max.