SR150-EI14 05/2015
SR150 V2.30
PARADOX.COM
Programming
Program the SR130 either though a supported keypad or through
BabyWare software (BabyWare).
Programming with Keypads
Programming with BabyWare
1.
Open BabyWare > Connect your Account.
2.
In the Main window: Select the
Add Item
button >
Wireless Sirens
.
3.
Fill-in the SR150 label, location and serial number.
4.
Select
Save.
Upgrading Firmware
Upgrade SR150 firmware through the Paradox In-Field software (V3.0 or
higher) using the 307USB Direct Connect Interface. The SR130 requires the
batteries installed in order to upgrade the firmware.
Note:
Ensure that the SR150 is awake before upgrading the firmware.
To wake up the siren
: press the Test button (see connector #7 in
Figure 1
). The siren provides a 60 second delay in order to begin
the update.
1.
Remove the front cover.
2.
Connect the 307USB to the In-Field connector (see connector #4 in
Figure 1
).
3.
Upgrade according to the firmware upgrade instructions: Go to
www.paradox.com >Software > In-Field Firmware Upgrade
Instructions.
Tamper Supervision
If a tamper is detected, the SR150 will sound an alarm and the strobe light
will flash for 4 minutes. The control panel will follow the global supervision
options set in the panel.
Specifications
Certifications
CE EN 50131-4 Grade 2 EN 50130-5 Class IV
Warranty
For complete warranty information on this product, please refer to the
Limited Warranty Statement found on the Statement. Your use of the
Paradox product signifies your acceptance of all warranty terms and
conditions. Please ensure that your use of the Paradox product is in
compliance with local, national, and international laws.
© 2015 Paradox Security Systems (Bahamas) Ltd. All rights reserved.
Specifications may change without prior notice. US, Canadian and
international patents may apply. BabyWare and Paradox are a trademarks
or registered trademarks of Paradox Security Systems (Bahamas) Ltd. or
its affiliates in Canada, the United States and/or other countries.
Feature
Program
MG6250
MG/SP
EVO192/HD
Sections correspond to sirens 1- 4.
EXAMPLE: [0802]: Learn Siren 2 for
MG6250
Sections
correspond to
sirens 1 - 8
Learn Siren
[0801] - [0804]
[683]
-
[686]
[2851]
-
[2858]
Press and hold the
Reset/Training
switch for 3
seconds after entering the section to learn the siren.
WARNING
: When pressing the Reset/Training switch,
the SR130 squawks and the strobe light flashes five
times to confirm siren registration to the panel
Assign
Partition to
Siren
-
-
[2861]
-
[2868]
Display Signal
Strength
[0801]
-
[0804]
[687]
-
[690]
[2871]
-
[2878]
Press and hold the
Reset/Training
switch for 3
seconds after entering the section to display the
siren signal strength that the panel receives.
Requires keypad K32LCD V1.3 or higher
Label Siren
[0811]
-
[0814]
[691]
-
[694]
-
Labels identify sirens when reporting events (for MG/
SP only: via e-mail through the IP100/ IP150. For
MG6250 through SMS personal reporting) and for
troubleshooting purposes. Maximum 16 characters
Temporary
Tamper Switch
Deactivation
for
Maintenance
[0800]
[695]
[2870]
Press
[ENTER]
after entering the section to
deactivate tamper alarm until the cover is reinstalled
or after 30 minutes
Panel
Supervision of
Siren
[0820]
[587]
-
ON
: Enabled (default)
OFF
: Disabled
The control panel supervises the presence of the
SR150. If lost, the control panel follows global
supervision options set in the control panel
Specification
Description
Power
4.5Vdc (3 “D” size alkaline batteries)
Optional: 8-16Vac / 9-20Vdc external power
Battery life
Up to 3 years based on normal use (e.g. 2 alarms
per year with strobe for 2.5 hours and 8 squawks
per day at an average of 25
º
C (77
º
F). Using optional
power source will extend battery life
Consumption
Sleep: 22uA, Standby: 130uA, Alarm: 550mA
RF frequency
433MHz or 868MHz
Siren
100dB (1 meter)
Dimensions
24cm X 6.cm X 18cm (9.5in X 2.3in X 7in)
Operating
Temperature
Battery only: -30ºC to 50ºC (-22ºF to 122ºF)
RF range
70m (229ft)