SR150-EI11 12/2012

SR150 V2.1

PARADOX.COM

Programming

 

Upgrading the Firmware

The SR150 firmware can be upgraded through WinLoad using the 307USB Direct Connect Interface. Refer to the firmware upgrade instructions found at: 
paradox.com - Software - WinLoad -Firmware Upgrade Instructions.

NOTE:

 Ensure that the SR150 Wireless Siren is awake before beginning the firmware upgrade. To wake up the siren, press the “test’ button. The siren will 

provide you with a 60 second delay in order to begin the update.

Tamper Supervision

If a tamper is detected, the SR150 will sound an alarm and the strobe light will flash for 4 minutes. The control panel will follow the global supervision 
options set in the panel.

For complete warranty information, please visit www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all warranty terms and conditions. Magellan, Spectra SP, EVO, and WinLoad are
trademarks or registered trademarks of Paradox Ltd. or its affiliates in Canada, the United States and/or other countries. For the latest product approvals, such as UL and CE, please visit www.paradox.com. © 2012 Paradox
Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, and RE39406 and
other pending patents may apply. Canadian and international patents may also apply. 
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. 

LED Feedback

Specifications

 

Power

4.5Vdc (3 size “D” alkaline batteries) 
Optional: 8-16Vac / 9-20Vdc external power

Battery life

Up to 3 years based on normal use (e.g. 2 alarms per year 
with strobe for 2.5 hours and 8 squawks per day at an 
average of 25

º

C (77

º

F). Using optional power source will 

extend battery life.

Consumption

Sleep: 22uA, Standby: 130uA, Alarm: 550mA

RF frequency

433MHz or 868MHz

Siren

100dB (1 meter)

Dimensions

24cm X 6.cm X 18cm (9.5in X 2.3in X 7in)

Operating 
Temperature

Battery only: -30ºC to 50ºC (-22ºF to 122ºF) 

RF range

70m (229ft)

Standards

EN 50131 Security Grade 2 Environmental Class IV

MG/SP

Feature

Details

[683]

Learn Siren #1

Press and hold “TEST” switch for 3 seconds after entering the section 
to learn the siren. 

WARNING:

 When you press the “TEST” switch, the SR150 will squawk and 

the strobe light will flash five times to confirm registration to the panel.

[684]

Learn Siren #2

[685]

Learn Siren #3

[686]

Learn Siren #4

[687]

Display Signal Strength Siren #1

Press and hold “Test” switch for 3 seconds after entering the section 
to display, on a K32LCD V1.3 or higher, the signal strength the panel is 
receiving from the siren. 

[688]

Display Signal Strength Siren #2

[689]

Display Signal Strength Siren #3

[690]

Display Signal Strength Siren #4

[691]

Label Siren #1

These labels are used when reporting events via e-mail through the 
IP100 and for troubleshooting purposes. Maximum 16 characters. 

[692]

Label Siren #2

[693]

Label Siren #3

[694]

Label Siren #4

[695]

Temporary Tamper Switch Deactivation for 
Maintenance

Press the 

[

ENTER

]

 key after entering the section to deactivate tamper 

alarm until the cover is replaced or after 30 minutes.

[587]

Panel Supervision of Siren

OFF = disabled     ON = enabled (default)

Option [3]

Siren #1 (OFF/ON)

The control panel supervises the presence of the SR150. If lost, the 
control panel will follow global supervision loss option set in the 
panel.

Option [4]

Siren #2 (OFF/ON)

Option [5]

Siren #3 (OFF/ON)

Option [6]

Siren #4 (OFF/ON)

TX

Sending data

RX

Receiving data

PSSI

Signal strength siren is receiving from panel 
Flash 4x - strong signal
Flash 3x - good signal
Flash 2x - weak signal
Flash 1x - very weak signal (relocate)
No flash - no signal

Status

Flash once/sec. - Processor is on
Flash once/4 sec. - Power save mode

Remove cover to view
LED status

Отзывы: