Step 3: Optional Settings

Partitioning

(to enable 2 partitions)

Enable Bell Squawk when arm/disarm

with Keypad / Generic Remote Control

Change Installer Code (Default: 0000)

Change Master Code (Default: 1234)

Reset All Programming to Default

Remote Control Assignment

611 for Rem#1, 612 for Rem#2,… up to 642 for Rem#32

Enroll Remote Control (REM15)

651 for Rem#1, 652 for Rem#2,.. Up to 682 for Rem#32

Step 4: Set Telephone Programming (Dial Out when alarm triggers)

Set Dialing attempts

Activate VDMP3 function*

Rings to pickup by panel*

*Only required if VDMP3 Voice Module installed

To be done in Standby Mode (Exit Programming Mode first):

Set to dial telephone #1

Set to dial telephone #2

Set to dial telephone #3

Set to dial telephone #4

Set to dial telephone #5

Step 5: Set Central Monitoring Station (CMS) Function

(only required if connected to ADT, CHUBB, PROTECS etc)

Set Contact ID Format

Set Account number Partition 1

Set Account number Partition 2

Set Telephone 1 (primary)

Set Telephone 2 (secondary)

Set Alternate Dial:

Set always report disarm

Set send daily test report

Set time for test signal

Step 6: Perform Walk Test

The Installer Test mode will allow you to perform walk tests where the siren will squawk to indicate opened zones.

To Activate: [ENTER] [INSTALLER CODE] [TBL] [CLEAR]

To DeActivate: [ENTER] [INSTALLER CODE] [TBL] [CLEAR]

Step 7: Hard Reset Panel

If settings have been entered wrongly and the panel does not work as desired, panel can be reset by doing the following:

i) Press & Hold Reset button on Main Panel for 5 seconds, then notice the Status LED blinking.

ii) Once blinking, quickly release the button and press again one time to reset to factory defaults.

Prepared by:

Belco Security Sdn Bhd

14, Jalan Intan 1, Taman Puchong Intan, 47150

Puchong, Selangor. Tel: 03-8062 3100   Fax: 03-9235 1118

651

Description

Command

Confirm

Timer & Option

611

950

ENTER, CLEAR

704

ENTER, CLEAR

399

397

700

New Code: XXXX

New Code: XXXX

(Default is OFF)

ON key [5]

Description

Command

Section

Timer & Option

Confirm

(Auto call the secondary number if primary 
number is busy)

ENTER

Telephone number 2

817

ENTER

Telephone number 1

815

4 digit Account number

812

Section

841

(Default is OFF)

ON key [1]

Press and Hold any button for 

2 times

ENTER, CLEAR

[1888] [8888]

ENTER

Command

Description

005

ENTER, CLEAR

ENTER, CLEAR

010

On key [8]

901

703

[    ] + [Master code] + [MEM] + [7] + [5th phone number] + ENTER, CLEAR

[    ] + [Master code] + [MEM] + [6] + [4th phone number] + ENTER, CLEAR

[    ] + [Master code] + [MEM] + [5] + [3rd phone number] + ENTER, CLEAR

[    ] + [Master code] + [MEM] + [4] + [2nd phone number] + ENTER, CLEAR

[    ] + [Master code] + [MEM] + [3] + [1st phone number] + ENTER, CLEAR

ENTER, CLEAR

4 digit Account number

811

4, 4

810

Confirm

Timer & Option

Section

ENTER, CLEAR

On key [4]

800

850

[ HH:MM ]

ENTER, CLEAR

001

840

ENTER, CLEAR

Off key [1]

801

Отзывы: