14
R
EFERENCE
& I
NSTALLATION
M
ANUAL
PART 4: ACCESS CODES
The Spectra 1759EX control panel supports the following access codes:
4.1
ACCESS CODE LENGTH
Section [127]: System Options
Option
[2]
OFF = 6-Digit Access Codes
Option
[2]
ON = 4-Digit Access Codes (default)
All access codes can be set to lengths of either 4- or 6-digits. When the 4-digit option is selected, entering a 4-digit code will allow
access. Using the 6-digit option, entering 6 digits is required to allow access.
If the Access Code Length is changed from four digits to six digits when access codes have already been
programmed, the control panel will automatically add the last 2 digits by using the first 2 digits. For example, if
the access code is 1234 and you switch to 6 digits, the code will become 123412. Be sure to verify the access
codes after switching from 4-digit access codes to 6-digit codes. When switching from six digits to four digits,
the control panel will simply remove the final two digits of the access code. For example, 123456 will become
1234.
4.2
INSTALLER CODE (Default: 000000)
The Installer Code is used to enter the control panel's programming mode (see page 11), which allows you to program all the
features, options and commands of the control panel. The Installer Code can be 4- or 6-digits in length (see above) where each
digit can be any value from 0 to 9. The Installer Code cannot be used to program Master Code 1, Master Code 2 or User Access
Codes. To program the Installer Code press:
[
ENTER
] + [
CURRENT
INSTALLER
CODE
] + [281] + new 4- or 6-digit Installer Code
4.3
SYSTEM MASTER CODE (Default: 123456)
The Installer Code can be used to program the System Master Code. With the System Master Code a user can use any arming
method and can program any User Access Code, but not the User Code Options. The System Master Code can be 4 or 6 digits
in length (see section 4.1), where each digit can be any digit from 0 to 9. To change the System Master Code press:
[
ENTER
] + [
INSTALLER
CODE
] + [301] + new 4- or 6-digit System Master Code
4.4
USER CODE OPTIONS
Sections
[302]
to
[348]
: Options
[1]
to
[7]
The User Code Options define which arming methods each user can use to arm or disarm the system. Regardless of these
settings, all users can Regular Arm assigned partitions and all users except those with the Arm Only option can disarm an
assigned partition, regardless of how it is armed. Select one or more of the options described on the following pages for each
User Access Code, where sections [302] to [348] represent User Access Codes 002 to 048. For information on how User Access
Codes are programmed, please refer to page 48.
4.4.1
P
ARTITION
1 A
SSIGNMENT
Sections [302] to [348]: User Codes 002 to 048
Option
[1]
OFF = Deny access to partition 1
Option
[1]
ON = User code has access to partition 1 (default)
If Partitioned (see page 41), user codes with this option enabled can arm and disarm partition 1.
If the system is not partitioned, you must assign partition 1 to the User Access Code. Otherwise, the
User Access Code will be considered disabled.
INSTALLER CODE:
Used to program all control panel settings except User Access Codes.
SYSTEM MASTER CODE (001)
Provides full access. Arm and disarm using any method described in the User Code Options
in section 4.4 as well as program the User Access Codes.
Master Code 1 (002):
Permanently assigned to partition 1. Same as a regular User Code except it can also
program access codes for User Codes assigned to partition 1.
Master Code 2 (003):
Permanently assigned to partition 2. Same as a regular User Code except it can program
access codes for User Codes assigned to partition 2. If the system is not partitioned Master
Code 002 will be assigned to partition 1.
45 User Codes (004 to 048):
Can arm and disarm as per User Code Options in section 4.4.