Page 10
Programming
*
For instructions on entering 3-digit RTX3 section numbers see
RTX3
Programming Sections for EVO Panels
on page 10.
RTX3 Programming Sections for EVO Panels
Section
Feature
Details
[001]
Option
[1]
Low battery
supervision
For RTX3 version 1.5 and higher, this
option is always on
ON
: default
[2]
Check-in
supervision
OFF
: default
[3]
Check-in
supervision time
interval
OFF
: 24 hours (default)
ON
: 80 minutes
[4]
RF Jamming
supervision
OFF
: default
[5]
On-board
module tamper
supervision
OFF
: default
[6]
PGM1 initial
state
OFF
: Normally Open (default)
ON
: Normally Closed
[7]
PGM2 initial
state
OFF
: Normally Open (default)
ON
: Normally Closed
[8]
Transmit tamper
signal
OFF
: RTX3 ignores tamper signal
(default)
ON
: RTX3 reports tamper signal
[002]
Remote Control Options
[1]
REM2 visual and
auditory
feedback
compatibility
options
*
OFF
: Old visual and auditory feedback
(Supported by REM2 v2.00 or
lower)
ON
: New visual and auditory feedback
(default)
Note
: Requires REM2 v2.01 and higher