LTE/4G/3G/2G Reporting Options

GSM Reporting (EBUS Connection)

Reporting Options

SMS Messages for Backup

 

Additional Programming Options

SMS Language

SMS Programming

Refer to the panel’s respective user manual for more information on 
SMS Personal Reporting.

List of SMS Commands

Please note that the default password is 

admin

.

EN Certification

The following statements apply for EN 50131 and EN 50136 

certification:

• Mode of operation is pass-through

• PCS265LTE must be installed and connected to an EN approved

Grade 3 control panel

• Monitoring of the transmission network interface (Internet

connection): In case of network/interface failure, the device sends

a trouble message to the control panel which then displays it via

connected keypad(s)

• Information Security is achieved by 256-bit encrypted, supervised

communication (AES validation number 986) which prevents

unauthorized reading or modification of messages

• Substitution Security is achieved by Information Security (as stated

above), physical security (Tamper protection) and by a unique

Serial Number from each device. Messages sent to the receiving

station include the S/N in order to identify the substitution and alert

accordingly

Technical Specifications

Safety Note: 

This device may operate continuously in temperature of 

55°C (

131°F)

 for a maximum period of 7 days.

MG/SP

EVO

Feature

Details

[918]
[919]

[2976] to 
[2983]

Account / Partition
Registration

MG/SP: Sections 
represent account/
partition 1 and 2
EVO: Sections 
represent account / 
partition 1 to 8

[806]

[2975]

[7] Off + [8] Off = landline only
[7] Off + [8] On = LTE/4G/3G/2G primary / land-
line backup (default)
[7] On + [8] Off = landline only
[7] On + [8] On = landline and LTE/4G/3G/2G in 
parallel

Receiver Settings

MG/SP

Receiver #:

IP address*

IP port ** 

IP address

WAN 2

IP port WAN2

Receiver password

Security Profile

1
[929]
[930]
[931]
[932]
[933]
[934]

2
[936]
[937]
[938]
[939]
[940]
[941]

Backup
[943]
[944]
[945]
[946]
[947]
[948]

Module registration

Press 

[ARM]

 to register

[935]

[942]

[949]

Receiver Settings

EVO

Receiver #:

IP address*

IP port **

IP address 

WAN 2

IP port WAN2

Receiver password

Security Profile

1

[2984]

2

[2986]

3

[2988]

4

[2990]

Module registration

Press 

[ARM]

 to register

[2985]

[2987]

[2989]

[2991]

* For 1 or 2 digit numbers, add “0’s” before the digit: e.g.,

138.002.043.006

** Default = 10000

Enter [MEM] for blank space

MG/SP

EVO

Details

[805]

[2950]

[1] Off + [2] Off = landline only (default)

[1] Off + [2] On = landline primary / GSM 

backup (default)

[1] On + [2] Off = GSM primary / landline 

backup

[1] On + [2] On = GSM only

[815] to
[817]

[3071] to 
[3074]

Telephone numbers

[811] to 
[812]

[3061] to
[3068]

Account numbers

Command

Description

P[PASSWORD].SMS[GSM MODEM 

TELEPHONE #].[IPRS-7 PASSWORD]

Used to program the 

receiver’s SMS parameters

Language

Value

Language

Value

English (default)

000

Bulgarian

016

French

001

Romanian

017

Spanish

002

Slovak

018

Italian

003

Chinese

019

Swedish

004

Serbian

020

Polish

005

Malay

021

Portuguese

006

Slovenian

022

German

007

Lithuanian

023

Turkish

008

Finnish

024

Hungarian

009

Estonian

025

Czech

010

French Canadian

026

Dutch

011

Belgian

027

Croatian

012

Latvian

028

Greek

013

Albanian

029

Hebrew

014

Macedonian

030

Russian

015

Section

SMS Site Name Label

EVO

[2954]

__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__

MG/SP

[780]

__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__

Command

Description

P[password].A[IP 

address].P[port number]

Used for LTE/4G/3G/2G remote 

access

P[password].IP.[call back phone 

number]

Used to obtain the IP address and IP 

port of the PCS265LTE and whether or 

not the “bandwidth saver” option is 

being used

P[password].RESET

Used to power cycle the PCS265LTE

P[password].STATUS.[phone

number]

Used to obtain the signal strength, 

signal quality, LTE/4G/3G/2G 

connection status, and APN 

settings of the current SIM card

P[password].

APN1.NAME.

[Access Point Name]

Used to program the SIM Card 1 APN 

P[password].

APN1.USER.

[Access Point Name]

Used to program the SIM card 1 APN 

User Name

P[password].

APN1.PSW.

[Access Point Name]

Used to program the SIM card 1 APN 

Password

P[password].

APN1.CLEAR]

Used to clear the SIM Card 1 APN

P[password].

VAPN1.[CALL BACK PHONE 

NUMBER]

Used to view the SIM Card 2 Access 

Point Name information

P[password]. APN2.NAME.

[Access Point Name]

Used to program the SIM Card 2 

Access Point Name

P[password].

APN2.USER.

[Access Point Name]

Used to program the SIM Card 2 

Access Point User

P[password].

APN2.PSW.

[Access Point Name]

Used to program the SIM Card 2 

Access Point Password

P[password].

APN2.CLEAR

Used to clear the SIM Card 2 Access 

Point Name

P[password].

VAPN2.[CALL BACK PHONE 

NUMBER]

Used to view the SIM Card 2 Access 

Point Name information

P[password].[IP1W1/ IP1W2/

IP2W1/ IP2W2/ IP3W1/ IP3W2/

IP4W1/ IP4W2].[domain name]

Set domain name for LTE/4G/3G/2G 

receiver

P[password].[IP1W1/ IP1W2/

IP2W1/ IP2W2/ IP3W1/ IP3W2/

IP4W1/ IP4W2]

.CLEAR

Clear domain name for LTE/4G/3G/2G 

receiver

C[user code].[ARM/OFF].A[area 

number], [area number], [area 

number]TO[area number]

Arm/Disarm

P[password].---S

Disable SWAN polling

(V4.10.011 and higher)

P[password].+++S

Enable SWAN polling

(V4.10.011 and higher)

Specifications

Description

RF Power

Class 4 (2W) @ 850/1900 MHz 
Class 2 (1W) @ 1800/1900 MHz 
UMTS 850/1900 @ 0.25W (America)
UMTS 900/2100 @ 0.25W (Europe)

Antenna Bandwidth

5 bands, wideband

Voltage Input

12 VDC nominal

Consumption during 
GPRS/GSM transmission

60 mA standby
300 mA maximum

Encryption

128-bit (AES)

SMS Protocol

7-bit (GSM: 3GPP TS 23.038/
GSM03.38)
or 16-bit (UCS2 ISO/IEC10646)

SIM Cards 

LTE/4G/3G 
GSM (2G - n/a for North and South 
America)

Humidity

0 - 90% non-condensing

Operating Temperature

-20 - 50 °C (-4 to 122 °F)

Dimensions

20.8 x 7.5 x 2 cm  / 8.2 x 2.9 x 0.8 in.

Certifications

EN 50136-1 EN 50136-2 Grade 3 
Class II EN 50131-10 ATS Category 
SP5 Certification Body: Applica Test 
and Certification

Command

Description

Warranty

The Limited Warranty Statement can be found on the website www.paradox.com/terms.

Patents

Your use of the Paradox product signifies your acceptance of these terms and

conditions.  The  following  US  patents  may  apply  5,886,632  and  6,215,399.

Other Canadian and international patents may apply.

©2022  Paradox  Security  Systems  (Bahamas)  Ltd.  All  rights  reserved.

Specifications may change without prior notice.

Отзывы: