![Paradox PCS265 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/paradox/pcs265/pcs265_installation-and-programming-manual_3621568002.webp)
PARADOX.COM
PCS265-EI04 03/2019
GSM Reporting (EBUS Connection)
Reporting Options
SMS Messages for Backup
Additional Programming Options
SMS Language
List of SMS Commands
Technical Specifications
Safety Note:
This device may operate continuously in temperature
of 55°C (
131°F)
for a maximum period of 7 days.
Receiver
Settings
MG/SP
Receiver #:
IP address*
IP port **
IP address
WAN 2
IP port WAN2
Receiver pass-
word
Security Profile
1
[929]
[930]
[931]
[932]
[933]
[934]
2
[936]
[937]
[938]
[939]
[940]
[941]
Backup
[943]
[944]
[945]
[946]
[947]
[948]
Module registra-
tion - Press
[ARM]
to register
[935]
[942]
[949]
Receiver
Settings
EVO
Receiver #:
IP address*
IP port **
IP address
WAN 2
IP port WAN2
Receiver pass-
word
Security Profile
1
[2984]
2
[2986]
3
[2988]
4
[2990]
* For 1 or 2 digit numbers, add “0’s” before the digit: e.g.,
138.002.043.006
** Default = 10000
Enter [MEM] for blank space
MG/SP
EVO
Details
[805]
[2950]
[1] Off + [2] Off = landline only (default)
[1] Off + [2] On = landline primary / GSM
backup (default)
[1] On + [2] Off = GSM primary / landline
backup
[1] On + [2] On = GSM only
[815] to
[817]
[3071] to
[3074]
Telephone numbers
[811] to
[812]
[3061] to
[3068]
Account numbers
Command
Description
P[PASSWORD].SMS[GSM MODEM
TELEPHONE #].[IPRS-7
PASSWORD]
Used to program the
receiver’s SMS parameters
Language
Value
Language
Value
English (default)
000
Bulgarian
016
French
001
Romanian
017
Spanish
002
Slovak
018
Italian
003
Chinese
019
Swedish
004
Serbian
020
Polish
005
Malay
021
Portuguese
006
Slovenian
022
German
007
Lithuanian
023
Turkish
008
Finnish
024
Hungarian
009
Estonian
025
Czech
010
French Canadian 026
Dutch
011
Belgian
027
Croatian
012
Latvian
028
Greek
013
Albanian
029
Hebrew
014
Macedonian
030
Russian
015
Command
Description
P[password].A[IP
address].P[port number]
Used for 4G/3G/2G remote access
P[password].IP.[call back
phone number]
Used to obtain the IP address and
IP port of the PCS265 and whether
or not the “bandwidth saver” option
is being used
P[password].RESET
Used to reset the PCS265
P[password].BWS.ON
Used to enable bandwidth saver
mode
P[password].BWS.OFF
Used to disable bandwidth saver
mode
P[password].VOLOUT.[GSM
output volume]
Used to set the GSM output
volume; values range between 50
to 100
P[password].STATUS.[phone
number]
Used to obtain the signal strength,
signal quality, 4G/3G/2G
connection status, and APN
settings of the current SIM card
P[password].APN1.NAME.
[AccessPoint Name]
Used to program the SIM Card 1
APN
P[password]
.APN1.USER.[Access
Point Name]
Used to program the SIM card 1
APN User Name
P[password]
.APN1.PSW.[Access
Point Name]
Used to program the SIM card 1
APN Password
P[password].APN1.CLEAR ] Used to clear the SIM Card 1 APN
P[password]
.VAPN1.NAME.[Access
Point Name]
Used to view the SIM card 1 APN
P[password].APN2.NAME.
[AccessPoint Name]
Used to program the SIM card 2
APN
P[password]
.APN2.USER.[Access
Point Name]
Used to program the SIM card 2
APN User Name
P[password]
.APN2.PSW.[Access
Point Name]
Used to program the SIM card 2
APN Password
P[password].APN2.CLEAR
Used to clear the SIM card 2 APN
P[password].VAPN2.[CALL
BACK PHONE NUMBER]
Used to view the SIM card 2 APN
information
Language
Value
Language
Value
P[password].[IP1W1/ IP1W2/
IP2W1/ IP2W2/ IP3W1/
IP3W2/
IP4W1/ IP4W2].[domain
name]
Set domain name for 4G/3G/2G
receiver
P[password].[IP1W1/ IP1W2/
IP2W1/ IP2W2/ IP3W1/
IP3W2/IP4W1/ IP4W2]
.CLEAR
Clear domain name for 4G/3G/2G
receiver
P[password].DNS.[ip
address]
Set domain name server (DNS) IP
address
P[password].DNS.CLEAR
Clear domain name server (DNS)
IP address
P[password].VIP.[phone
number]
Get domain name server (DNS) info
C[user code].[ARM/
OFF].A[area
number], [area number], [area
number]TO[area number]
Arm/Disarm
P
[
password].---S
Disable SWAN polling
(V4.32.002 and higher)
P[password].+++S
Enable SWAN polling
(V4.32.002 and higher)
Specifications
Description
RF Power
Class 4 (2W) @ 850/1900 MHz
Class 2 (1W) @ 1800/1900 MHz
UMTS 850/1900 @ 0.25W
(America)
UMTS 900/2100 @ 0.25W (Europe)
Antenna Bandwidth
5 bands, wideband
Voltage Input
12 VDC nominal
Consumption during
GPRS/GSM transmission
60mA standby
300 mA maximum
Encryption
128-bit (AES)
SMS Protocol
7-bit (GSM: 3GPP TS 23.038/
GSM03.38)
or 16-bit (UCS2 ISO/IEC10646)
SIM Cards
4G/3G
GSM (2G - n/a for North and South
America)
Humidity
0 - 90% non-condensing
Operating Temperature
-20 - 50 °C (-4 to 122 °F)
Dimensions
20.8 x 7.5 x 2 cm / 8.2 x 2.9 x 0.8 in.
Certifications
EN 50131-1 Grade 3 Class II, EN
50136-1 ATS Category SP5
Command
Description
Warranty
The Limited Warranty Statement can be found on the website www.paradox.com/
terms.
Patents
Your use of the Paradox product signifies your acceptance of these terms and
conditions. The following US patents may apply 5,886,632 and 6,215,399. Other
Canadian and international patents may apply.
©2019 Paradox Security Systems (Bahamas) Ltd. All rights reserved.
Specifications may change without prior notice.