GSM Reporting (EBUS Connection)

Reporting Options

SMS Messages for Backup

 

Additional Programming Options

SMS Language

List of SMS Commands

Technical Specifications

Safety Note: 

This device may operate continuously in temperature 

of 55°C (

131°F)

 for a maximum period of 7 days.

Receiver 
Settings

MG/SP

Receiver #:
IP address*
IP port ** 
IP address
WAN 2
IP port WAN2
Receiver pass-
word
Security Profile

1
[929]
[930]
[931]
[932]
[933]
[934]

2
[936]
[937]
[938]
[939]
[940]
[941]

Backup
[943]
[944]
[945]
[946]
[947]
[948]

Module registra-
tion - Press 

[ARM]

 to register

[935]

[942]

[949]

Receiver 
Settings

EVO

Receiver #:
IP address*
IP port **
IP address 
WAN 2
IP port WAN2
Receiver pass-
word
Security Profile

1

[2984]

2

[2986]

3

[2988]

4

[2990]

* For 1 or 2 digit numbers, add “0’s” before the digit: e.g., 
138.002.043.006
** Default = 10000
Enter [MEM] for blank space

MG/SP

EVO

Details

[805]

[2950]

[1] Off + [2] Off = landline only (default)
[1] Off + [2] On = landline primary / GSM 
backup (default)
[1] On + [2] Off = GSM primary / landline 
backup
[1] On + [2] On = GSM only

[815] to
[817]

[3071] to 
[3074]

Telephone numbers

[811] to 
[812]

[3061] to
[3068]

Account numbers

Command

Description

P[PASSWORD].SMS[GSM MODEM 

TELEPHONE #].[IPRS-7 

PASSWORD]

Used to program the 
receiver’s SMS parameters

Language

Value

Language

Value

English (default)

000

Bulgarian

016

French

001

Romanian

017

Spanish

002

Slovak

018

Italian

003

Chinese

019

Swedish

004

Serbian

020

Polish

005

Malay

021

Portuguese

006

Slovenian

022

German

007

Lithuanian

023

Turkish

008

Finnish

024

Hungarian

009

Estonian

025

Czech

010

French Canadian 026

Dutch

011

Belgian

027

Croatian

012

Latvian

028

Greek

013

Albanian

029

Hebrew

014

Macedonian

030

Russian

015

Command

Description

P[password].A[IP 
address].P[port number]

Used for 4G/3G/2G remote access

P[password].IP.[call back 
phone number]

Used to obtain the IP address and 
IP port of the PCS265 and whether 
or not the “bandwidth saver” option 
is being used

P[password].RESET

Used to reset the PCS265

P[password].BWS.ON

Used to enable bandwidth saver 
mode

P[password].BWS.OFF

Used to disable bandwidth saver 
mode

P[password].VOLOUT.[GSM 
output volume]

Used to set the GSM output 
volume; values range between 50 
to 100

P[password].STATUS.[phone
number]

Used to obtain the signal strength, 
signal quality, 4G/3G/2G 
connection status, and APN 
settings of the current SIM card

P[password].APN1.NAME.
[AccessPoint Name]

Used to program the SIM Card 1 
APN 

P[password]
.APN1.USER.[Access
Point Name]

Used to program the SIM card 1 
APN User Name

P[password]
.APN1.PSW.[Access
Point Name]

Used to program the SIM card 1 
APN Password

P[password].APN1.CLEAR ] Used to clear the SIM Card 1 APN
P[password]
.VAPN1.NAME.[Access
Point Name]

Used to view the SIM card 1 APN

P[password].APN2.NAME.
[AccessPoint Name]

Used to program the SIM card 2 
APN

P[password]
.APN2.USER.[Access
Point Name]

Used to program the SIM card 2 
APN User Name

P[password]
.APN2.PSW.[Access
Point Name]

Used to program the SIM card 2 
APN Password

P[password].APN2.CLEAR 

Used to clear the SIM card 2 APN

P[password].VAPN2.[CALL 
BACK PHONE NUMBER]

Used to view the SIM card 2 APN
information

Language

Value

Language

Value

P[password].[IP1W1/ IP1W2/
IP2W1/ IP2W2/ IP3W1/ 
IP3W2/
IP4W1/ IP4W2].[domain 
name]

Set domain name for 4G/3G/2G 
receiver

P[password].[IP1W1/ IP1W2/
IP2W1/ IP2W2/ IP3W1/ 
IP3W2/IP4W1/ IP4W2]
.CLEAR

Clear domain name for 4G/3G/2G 
receiver

P[password].DNS.[ip 
address]

Set domain name server (DNS) IP 
address

P[password].DNS.CLEAR

Clear domain name server (DNS) 
IP address

P[password].VIP.[phone 
number]

Get domain name server (DNS) info

C[user code].[ARM/
OFF].A[area
number], [area number], [area
number]TO[area number]

Arm/Disarm

P

[

password].---S

Disable SWAN polling

(V4.32.002 and higher)

P[password].+++S

Enable SWAN polling
(V4.32.002 and higher)

Specifications

Description

RF Power

Class 4 (2W) @ 850/1900 MHz 
Class 2 (1W) @ 1800/1900 MHz 
UMTS 850/1900 @ 0.25W 
(America)
UMTS 900/2100 @ 0.25W (Europe)

Antenna Bandwidth

5 bands, wideband

Voltage Input

12 VDC nominal

Consumption during 
GPRS/GSM transmission

60mA standby
300 mA maximum

Encryption

128-bit (AES)

SMS Protocol

7-bit (GSM: 3GPP TS 23.038/
GSM03.38)
or 16-bit (UCS2 ISO/IEC10646)

SIM Cards 

4G/3G 
GSM (2G - n/a for North and South 
America)

Humidity

0 - 90% non-condensing

Operating Temperature

-20 - 50 °C (-4 to 122 °F)

Dimensions

20.8 x 7.5 x 2 cm  / 8.2 x 2.9 x 0.8 in.

Certifications

EN 50131-1 Grade 3 Class II, EN 
50136-1 ATS Category SP5

Command

Description

Warranty

The Limited Warranty Statement can be found on the website www.paradox.com/

terms.

Patents

Your use of the Paradox product signifies your acceptance of these terms and

conditions. The following US patents may apply 5,886,632 and 6,215,399. Other

Canadian and international patents may apply.

©2019 Paradox Security Systems (Bahamas) Ltd. All rights reserved.

Specifications may change without prior notice.

Отзывы: