manualshive.com logo in svg
background image

Wireless Receiver Module V1.1

Reference & Installation Manual

Содержание omnia OMN-RCV3

Страница 1: ...Wireless Receiver Module V1 1 Reference Installation Manual ...

Страница 2: ......

Страница 3: ...0 SUPERVISION OPTIONS 10 Check In Supervision 10 Check In Supervision Timer Settings 11 Low Battery Supervision 12 On Board Module Tamper Supervision Zone Assignment 12 PROGRAMMABLE OUTPUTS PGMs 13 PGM Activation 13 PGM Deactivation 13 REMOTE CONTROL PROGRAMMING 14 Assigning a Remote Control to the Receiver Module 14 Assigning the Remote Controls to User Access Codes 15 Programming the Remote Cont...

Страница 4: ......

Страница 5: ...emote controls 300ft 100m Sensitivity 120 dBm Current consumption 50 mA Dimensions no antenna 15cm H x 16cm L x 3cm W 6in H x 6 5in L x 1 1in W Operating temperature 0 C to 50 C 32 F to 122 F Operating humidity 85 PGM outputs 1 relay 1 additional PGM output is available PGM output current 5A Approvals 1 2 SYSTEM FEATURES Auto Panel Recognition Add 8 wireless motion detectors and or door contacts t...

Страница 6: ...tion Manual for maximum allowable distances between the control panel and the Wireless Receiver Module 2 2 CONNECTIONS AND MOUNTING Firmly screw the antenna into the connector marked ANT on the Receiver Module as shown in Figure 2 1 on page 5 Using a drill or screwdriver punch out the four mounting holes on the back of the plastic case Align the six holes of the printed circuit board with the six ...

Страница 7: ...Omnia 5 Figure 2 1 Connecting the OMN RCV3 to the control panel ...

Страница 8: ...order to ensure proper synchronization between the transmitters and receiver open and close the transmitters covers and zones 3 1 HOW TO ENTER PROGRAMMING MODE Programming of the OMN RCV3 is done in Programming Mode through any keypad connected to the Spectra control panel The OMN RCV3 s programming guide can be found in the appropriate Spectra Programming Guide 3 2 WIRELESS TRANSMITTER PROGRAMMIN...

Страница 9: ...ogramming Guide Table 3 1 Sections and Expansion Inputs Do not assign detection devices from different modules to the same expansion input For example do not assign a wireless transmitter to section 601 then connect a detection device to input Z1 of the APR3 ZX8 Section 6 digit Serial Number Expansion Input 601 ___ ___ ___ ___ ___ ___ Input 1 602 ___ ___ ___ ___ ___ ___ Input 2 603 ___ ___ ___ ___...

Страница 10: ...nstallation Manual for instructions on programming the zones 3 3 VIEWING THE TRANSMITTER SIGNAL STRENGTH SECTIONS 631 TO 638 Once the detectors and or door contacts have been installed and assigned to the Receiver Module the signal strength of each transmitter can be verified in sections 631 to 638 Each section represents the signal strength viewer for a specific device For example section 631 is ...

Страница 11: ... a transmitter s signal strength In step 3 in section 3 1 on page 6 1 Enter the desired SECTION NUMBER 631 to 638 2 Press the transmitter s tamper switch or open the corresponding zone On an LED keypad The keypad will illuminate numbers 1 to 8 On an LCD keypad The keypad will display from 1 to 8 characters on the screen For example in the figure below the LCD screen shows a signal strength reading...

Страница 12: ...unctionality If a device has not sent a signal within that time period the Wireless Receiver Module will transmit a supervision loss signal to the control panel The control panel can then generate a trouble an alarm and or can transmit How to view unknown transmitter serial numbers In step 3 in section 3 1 on page 6 1 Enter section 630 2 Press the tamper switch of any Omnia wireless motion detecto...

Страница 13: ...iod defined here it can send a Supervision Loss signal to the control panel Refer to section 4 1 for instructions on enabling check in supervision The assigned transmitters must be set to the same Check In timer setting as the Receiver For example if the Receiver Check In timer is set at 12 hours the transmitters Check In timers must also be 12 hours How to enable check in supervision In step 3 in...

Страница 14: ... the control panel via the communication bus The Zone Tamper report code will originate from the zone defined by the Expansion Input 001 008 you have programmed in section 615 Please note that the corresponding zone must be programmed refer to the appropriate Spectra Reference Installation Manual for more details For example when you program 003 Expansion Input 3 in section 615 of a Spectra 1728 p...

Страница 15: ...lly refer to section 5 2 the button used to activate the PGM will also be used to deactivate the PGM 5 2 PGM DEACTIVATION SECTION 610 OPTIONS 6 AND 7 Once a PGM has been activated refer to section 5 1 options 6 and 7 determine how the respective PGM will deactivate If the option is OFF the activated PGM will automatically deactivate after 2 seconds If the option is ON the activated PGM can only be...

Страница 16: ...ssigned to User Access Codes in sections 701 to 708 3 The remote control s buttons are programmed in sections 711 to 718 The remote control will transmit a signal for only 1 second when a button is pressed This is done to conserve the remote control s batteries 6 1 ASSIGNING A REMOTE CONTROL TO THE RECEIVER MODULE SECTIONS 721 731 TO 728 738 Remote controls are assigned to the module using the Aut...

Страница 17: ...BUTTONS SECTIONS 711 TO 718 Each remote control can be programmed to send a signal to the control panel to perform up to 8 different actions Each digit in sections 711 to 718 represents a button or combination of buttons refer to Table 6 1 on page 16 When a user arms or disarms using the remote control the control panel will arm or disarm all the areas assigned to the User Access Code For example ...

Страница 18: ...time to save and exit Note To delete the hexadecimal values in a particular section 711 718 press the FORCE button once for every value Remote Control Button Programming refer to Table 6 2 Section 711 ____ ____ ____ ____ ____ ____ ____ ____ A B C D A B C D A C B D remote control 1 712 ____ ____ ____ ____ ____ ____ ____ ____ A B C D A B C D A C B D remote control 2 713 ____ ____ ____ ____ ____ ____...

Страница 19: ...e Event Group 08 as their Activation Event 6 Disarm when there is no alarm D Activates any PGMs that have Event Group 09 as their Activation Event Value or Action What Do I Press What Do I See 10 Zone LED 16 Zone LED LCD Values 1 to 9 1 to 9 1 to 9 1 to 9 1 to 9 A hexa only 0 0 10 10 0 B hexa only STAY STAY 11 B C hexa only BYP BYP 12 C D hexa only MEM MEM 13 D E hexa only TBL TRBL TBL 14 E F hexa...

Страница 20: ...iate Force Arming user option Also if you enable any Panic button options you must enable the Panic options in the Spectra control panel refer to the appropriate Spectra Reference Installation Manual 6 4 DELETING REMOTE CONTROLS SECTIONS 721 731 TO 728 738 For installations using a Spectra control panel version 1 23 or lower How to delete a remote control Spectra version 1 23 or lower In step 3 in...

Страница 21: ...esired SECTION NUMBER 731 to 738 2 Press the FORCE button How to replace the remote control batteries 1 Remove the two screws from the back of the remote control and remove the back cover 2 Remove the old batteries from inside the remote control 3 Replace with two 3V lithium batteries CR2016 ensuring proper polarity The positive of the batteries is inserted face down 4 Set the back cover in place ...

Страница 22: ... value Option 6 PGM1 deactivation mode Option 7 PGM2 deactivation mode 615 On board module tamper supervision zone assignment 630 View unknown serial numbers 631 to 638 View the detector and door contact signal strengths 701 to 708 Assign the remote controls to user access codes 711 to 718 Programming the remote control buttons 721 to 728 731 to 738 Assign a remote control to the receiver For Spec...

Страница 23: ... in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expressly limited to repairing or replacing at Seller s option any product not meeting the specifications In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indir...

Страница 24: ...NOTES ...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Отзывы: