Magellan / Spectra SP
41
Installer Function Keys
Use the following instructions to access the Installer Function features.
RF jamming
3 344 - RF receiver jam detection
XH - RF Jamming Restoral
GSM/GPRS module Rf interference restore
3 552 - Radio transmitter restore
YK - Communication restore
GSM/GPRS network restore
3 552 - Radio transmitter restore
YK - Communication restore
GSM/GPRS supervision restore
3 552 - Radio transmitter restore
YK - Communication restore
GSM/GPRS fail to communicate restore
3 354 - Communication restore
YK - Fail to communicate restore
IP network restore
3 552 - Radio transmitter restore
YK - Communication restore
IP supervision restore
3 552 - Radio transmitter restore
YK - Communication restore
IP fail to communicate restore
3 354 - Communication restore
YK - Fail to communicate restore
Combus fault
1 333 - Expansion module failure
ET - Expansion trouble
Module tamper
1 341 - Expansion module tamper
TA - Tamper alarm
Module AC fail
1 342 - AC failure on module
AT - Module AC fail
Module battery fail
1 338 - Battery failure on module
YT - Module battery fail
Bus fault restore
3 333 - Expansion module failure restore
ER - Expansion restoral
Module tamper restore
3 341 - Expansion module tamper restore
TR - Tamper restoral
Module AC fail restore
3 342 - AC restored on module
AR - Module AC fail restore
Module battery fail restore
3 338 - Battery failure on module
YR - Module battery fail restore
Cold start
1 3A8 - System shutdown
RR - Power up
Test report engaged
1 6A2 - Periodic test report
TX - Test report
PC software communication finished
1 412 - Successful - download access
RS - Remote program success
Installer on site
1 627 - Program mode entry
LB - Local program
Installer programming finished
1 628 - Program mode exit
LS - Local program success
Maintenance in
1 627 - Program mode entry
LB - Local program
Maintenance out
1 628 - Program mode exit
LS - Local program success
Closing delinquency
1 654 - System inactivity
CD - System inactivity
Manual trigger test in
1 6A1 - Manual trigger test in
TS - Manual trigger test in
Manual trigger test out
3 6A1 - Manual trigger test out
TS - Manual trigger test out
Exit error
1 374 - Exit error
EE - Exit error
RF module low battery
1 384 - RF transmitter low battery
XT - Transmitter battery trouble
RF module battery restore
3 384 - RF transmitter battery restore
XR - Transmitter battery restoral
RF zone supervision lost
1 381 - Loss of supervision - RF
US - Untype zone supervision
RF zone supervision restore
3 381 - Supervision restore - RF
UR - Untyped zone restoral
RF module supervision lost
1 381 - Loss of supervision- RF
US - Untype zone supervision
RF module supervision restore
3 381 - Loss of supervision- RF restore
UR - Untyped zone restoral
RF module tamper
1 145 - Expansion module tamper
ES - Expansion device tamper
RF module tamper restore
3 145 - Expansion module tamper restore
EJ - Expansion device restore
Paramedic alarm
1 1AA - Medical
MA - Medical alarm
Zone forced
1 57A - Zone forced
XW - Zone forced
Zone included
3 57A - Zone included
UU - Zone included
Function
Action
Description
Test Report
[
ENTER
]+[
INSTALLER
CODE
] + [
MEM
]
Send the “Test Report” report code programmed in section
[875]
(page 38) to the monitoring station
Cancel Communication
[
ENTER
]+[
INSTALLER
CODE
] + [
STAY
]
Cancels all communication with the WinLoad / BabyWare software or
with the monitoring station until the next reportable event
Answer WinLoad /
BabyWare Software
[
ENTER
]+[
INSTALLER
CODE
] + [
SLEEP
]
Will force the console to answer an incoming call from the monitoring
station that is using the WinLoad / BabyWare software
Call WinLoad / BabyWare
Software
[
ENTER
]+[
INSTALLER
CODE
] + [
BYP
]
Will dial the PC telephone number programmed in section
[915]
(page 22) in order to initiate communication with a computer using
the WinLoad / BabyWare software
Installer Test Mode
[
ENTER
]+[
INSTALLER
CODE
] + [
TBL
]
The installer test mode will allow you to perform walk tests where the
siren will squawk to indicate opened zones. Press the
[
TBL
]
key
again to exit
System Event
Default Contact ID Report Code
Default SIA Report Code
Содержание MG5050