Magellan Wireless Expansion Module
17
The check-in time in the Magellan wireless transmitters is a
fixed value.
6.3 Tamper Supervision
The MG-RCV3 comes equipped with an on-board anti-tamper switch. If the
Tamper Supervision feature is enabled and the module’s cover is removed, the
on-board anti-tamper switch (refer to Figure 2.2 on page 6) will be triggered.
When this occurs, the MG-RCV3 will send a tamper signal to the control panel.
The control panel can then generate a trouble, an alarm and/or can transmit a
report code to the monitoring station.
For more information, refer to the
Spectra
,
Digiplex
or
DigiplexNE
Reference & Installation Manual
.
How to program the check-in supervision time interval:
Spectra
In step 3 in section 3.1 on page 8:
1. Enter section
[610]
.
2. Enable or disable option
[2]
.
Option [2]
OFF
= 24 hours (default)
Option [2]
ON
= 80 minutes
Digiplex Series
In step 5 in section 3.2 on page 8:
1. Enter section
[001]
.
2. Enable or disable option
[3]
.
Option [3]
OFF
= 24 hours (default)
Option [3]
ON
= 80 minutes
MGRCV3SD_EI01.fm Page 17 Thursday, May 5, 2005 2:22 PM