30
Reference & Installation Manual
•
The console will repeat the message a programmed amount
of times (see Voice Message Repetitions on page 30) if no
acknowledgement is immediately received.
•
If no acknowledgement is received before the number of
repetitions has elapsed, the console will then call the next
programmed Voice Message telephone number and repeat
the process.
•
After calling the last programmed Voice Message telephone
number without an acknowledgement, the console will once
again call the first Voice Message telephone number and
repeat the process a maximum of three times.
•
If no acknowledgement is received after the third time, the
console will generate a Fail to Comm. event and trouble.
* The speakerphone feature is only available with the MG-6160.
Voice Message Repetitions
Section [079]: 001 to 010 repetitions; Default = 3 repetitions;
Maximum = 10 repetitions
This feature determines the amount of times the console will
repeat the pre-recorded message played with the Voice
Message telephone number without receiving an
acknowledgement. Enter any 3-digit number from 001 to
010 into section [079] to program the Voice Message
Repetitions feature.
Service Telephone Number
Section [116]
When a specific trouble occurs (Fail to Comm., Console Tamper
or Supervision Loss), the console will offer you the option of
calling the telephone number programmed in section [116]. After
selecting the option, the console becomes a speakerphone*.
* The speakerphone feature is only available with the MG-6160.
Refer to the Magellan User Guide for more information
on using this feature.
Utility Reporting
Within the Utility Reporting menu, customize what events and
when these events will be reported to the user. One of five report
types can be programmed to have the Magellan console call the
user on up to two different telephone numbers with a pre-
recorded voice message when certain conditions are met. Once
the telephone call from the Magellan console is received, the [#]
key on the telephone can be pressed twice to acknowledge and
end the message or the [1] can be pressed to use the
speakerphone feature* and talk through the Magellan console.
* The speakerphone feature is only available with the MG-6160.
To program the Utility Reporting feature using the Magellan
console:
1. Press [
MENU
] and then press the [4] key.
2. Enter the [
INSTALLER
CODE
] and then press the [3] key.
3. Press [
NEXT
] until the Utility Reporting screen appears, then
press [
OK
].
4. Press [
NEXT
] until the desired telephone number appears,
then press [
OK
].
5. Enter the desired telephone number and then press [
OK
]
twice.
6. Press [
NEXT
] until the desired report type appears, then
press [
OK
] (see Report Types on page 30).
7. Press [
NEXT
] until the Record Alrm Mes? screen appears,
then press [
OK
].
8. Record the alarm message.
Report Types
There are four report types that can be used with Utility
Reporting.
•
Disarm with user: The Magellan console calls the user
when specific users disarm the system.
•
System troubles: The Magellan console calls the user
when specific troubles appear.
•
Paramedic alarm: The Magellan console calls the user
when specific users require non-medical emergency
assistance and press the appropriate key on their
remote controls.
•
Zone activation: The Magellan console calls the user
when a specific zone is breached or opened.
•
Panic: There are four types of panic: Emergency,
Auxiliary, Fire, and Duress Alarm.
Refer to the Magellan User Guide for more information
on using this feature.
Console Account Number
Section [107]
All report codes are preceded by a 4-digit or 3-digit Console
Account Number to ensure correct identification of the Magellan
console. The Console account number can be any hexa-digit
from 1 to F. To enter a 3-digit account number, simply press the
[1] key from the center keypad, followed by the 3-digit account
number. Also, when using 3-digit account numbers, you must
use 1-digit report codes.
Reporting Formats
Section [105] = Reporting format for MSTN 1
Section [106] = Reporting format for MSTN 2
The reporting formats apply only to the MSTNs (Monitoring
Station Telephone Numbers) programmed in sections [111] and
[112] (page 29)
The Magellan console can use a number of different reporting
formats and each monitoring station telephone number can be
programmed with a different reporting format. The three digits
entered into section [105] represent the reporting format used to
communicate with Monitoring Station Telephone Number 1 while
the three digits entered into section [106] represent the reporting
format used to communicate with Monitoring Station Telephone
Number 2.
Table 8: Reporting Formats
3-digit Value
Reporting Format
001
Ademco slow (1400Hz, 1900Hz, 10BPS)
002
Silent Knight Fast (1400Hz, 1900Hz, 10BPS)
003
SESCOA (2300Hz, 1800Hz, 20BPS)
004
Ademco Contact ID