background image

User Guide

We hope this product performs to your complete satisfaction. Should you have any 

questions or comments, please visit www.paradox.com and send us your comments.

MG5000
MG5050

SP5500
SP6000
SP7000

Содержание Magelan MG5000

Страница 1: ...ser Guide We hope this product performs to your complete satisfaction Should you have any questions or comments please visit www paradox com and send us your comments MG5000 MG5050 SP5500 SP6000 SP700...

Страница 2: ...15 _____________________________________ ________ N N N N N Duress Y N N N 016 _____________________________________ ________ N N N N N Duress Y N N N 017 _____________________________________ _______...

Страница 3: ...Goes to next available user Notes By default User 1 has access to both partitions User 2 has access to partition 1 only and User 3 has access to partition 2 only These settings cannot be modified Ste...

Страница 4: ...rt to the monitoring station Step Action Details 1 MASTER CODE The key will flash PARTITION MASTER CODE may also be used 2 BYP 3 1 Auto arm partition 1 2 Auto arm partition 2 4 HH MM Enter time 24Hr c...

Страница 5: ...ular Arming 9 Sleep Arming 9 Stay Arming 9 One Touch Arming 10 Auto Arming 10 Disarming Deactivating an Alarm 11 Manual Bypass Programming 11 System Features 12 Display Mode 12 Alarm Display 12 Fire A...

Страница 6: ...ode the keypad produces an intermittent beep tone BEEP BEEP BEEP BEEP Rejection Beep When the system reverts to its previous status or when an operation is incorrectly entered on the keypad it will em...

Страница 7: ...hold to set chime zones see page 13 TBL Trouble display ON Trouble s occurring MEM Alarm memory display ON Alarm s occurred BYP Bypass programming ON Zone s bypassed Zone Display The numbers 1 to 32 c...

Страница 8: ...and many of your system s features can be assigned to either Partition 1 Partition 2 or both partitions If the system is not partitioned all zones user codes and features will be recognized as belong...

Страница 9: ...that the exit path is assigned to This will start an exit delay period for all zones in the exit path After you have left the property all exit path zones will rearm The system is now in Full mode Ent...

Страница 10: ...mmediately transmit a silent alert Duress Code to the monitoring station Must be enabled by your installer Programming Access Codes Your system can be programmed to use either 4 or 6 digit access code...

Страница 11: ...ee Auto Arming on page 10 or One Touch arming see One Touch Arming on page 10 Stay Arming This method allows you to roam freely within the premises while the perimeter is fully armed Stay zones are zo...

Страница 12: ...Mode See Manual Bypass Programming on page 11 Fast Exit When the system is already Stay or Sleep armed This feature will allow you to exit already armed premises and keep the system armed Press and ho...

Страница 13: ...ey will illuminate If One Touch Bypass Programming is enabled press the BYP key for three seconds to enter Bypass Programming Press ENTER after step 2 to bypass all open zones Press CLEAR twice to exi...

Страница 14: ...king fires often result from unattended cooking and human error rather than mechanical failure of stoves or ovens Careless smoking is the leading cause of fire deaths Smoke detectors and smolder resis...

Страница 15: ...e PGM Press and hold CLEAR ENTER or for three seconds to perform a smoke reset These features must be set by your installer How do I chime zones MG32LED MG32LRF 32 zone hardwired wireless LED keypad m...

Страница 16: ...Failure A wiring problem is occurring on one or more zones 6 Module Tamper Trouble A module s anti tamper switch has been triggered 7 Fire Loop Trouble Indicates a wiring trouble on a fire zone 8 Time...

Страница 17: ...ad software Cancel Communication MEM 9 Cancels all communication with the WinLoad software if it has been initiated Testing Maintenance With the system disarmed and the OFF light illuminated activate...

Страница 18: ...________________ ______ N N N N N N Fire Zone Y N N N Delayed Y N N N 16 ___________________________________ ______ N N N N N N Fire Zone Y N N N Delayed Y N N N 17 ___________________________________...

Страница 19: ...cerns would include without limitation Internet connection failures which may be more frequent than regular telephone line outages We therefore strongly recommend that you discuss these and other limi...

Страница 20: ...paradox com Printed in Canada 07 2007 MGSP EU08...

Отзывы: