IP150 Internet Module
Installation Manual V1.3 - IP150-EI01
Printed in Canada 08/2013
Description
The IP150 Internet Module is an HTTPs-supported IP communication device that enables you to
control and monitor your security system through any web browser (e.g., Google Chrome). The
IP150 provides freedom to access your system and receive instant, SSL encrypted email notifica-
tions anywhere in the world when your system detects activity. So no matter where you are, you
will have access to arm,
disarm, and more.
Before You Begin
Before you begin, make sure that you have web-enabled computer. You will also require the fol-
lowing system requirements in order to configure to your IP150 Internet Module. System require-
ments include:
•
Ethernet-compatible computer with internet access (required for remote access)
•
Router
•
4-pin serial cable (included)
•
CAT-5 Ethernet cable (maximum 90m (295 ft.), not included)
•
Paradox IP Exploring Tools Software (required for remote access).
Software can be downloaded
from our website (www.paradox.com/GSM/IP/Voice/IP).
Figure 1: IP Communication Overview
Connecting and Installing the IP150
Figure 2: IP150 Overview
@
Email Notification
Home PC
Router
Router
Web Access
IPR512
IP Receiver
Monitoring
Station
Control Panel
IP150
WAN
Front View
Right Side View
Left Side View
Metal Box Installation
To connect and install the IP150:
1)
Connect the 4-pin serial cable between the panel’s serial connector and the IP150’s panel con-
nector (see
Right Side View
in Figure 2).
2)
Connect the Ethernet cable between the router and the IP150’s network connector (see
Left
Side View
in Figure 2).
3)
The onboard LEDs will illuminate to indicate the IP150’s status (see
Front View i
n Figure 2).
4)
Clip the IP150 to the top of the metal box
(see
Metal Box Installation
in Figure 2).
LED Indicators
Reset IP150 to Default
To reset the IP150 module to its default settings, insert a pin/straightened paper clip (or similar)
into the pin hole located between the two I/O LEDs. Press down gently until you feel some
resistance; hold it down for approximately 5 seconds, release it when the I/O and RX/TX LEDs start
flashing, and then press it again. The I/O and RX/TX LEDs will remain lit during the reset.
IP Reporting
When using IP reporting, the IP150 has the ability to poll the monitoring station. To enable IP
reporting, the IP150 must first be registered to the monitoring station’s IP Receiver (IPR512). Tele-
phone reporting can be used in conjunction with, or as a backup to IP reporting. Before registering
the IP150, the following information must be obtained from the monitoring station:
•
Account number(s) - One account number for each partition used. IP/GPRS reporting uses a
different set of account numbers than those used for dialer reporting.
•
IP address(es) - (12-digit number e.g., for 195.4.8.250 you must enter 195.004.008.250)
•
The IP address(es) indicate(s) which of the monitoring station’s IP Receivers will be used for IP
reporting.
•
IP port(s) (5-digit number; for 4-digit numbers, enter 0 before the first digit). The IP port refers
to the port used by the monitoring station’s IP Receiver.
•
Receiver password(s) (up to 32-digits)
•
The receiver password is used to encrypt the IP150 registration process.
•
Security profile(s) (2-digit number). The security profile indicates how frequently the monitoring
station is polled by the IP150. Security profile numbers and polling frequency are defined by the
monitoring station.
Setting Up IP Reporting
1)
Ensure that the panel’s report code format is set to Ademco Contact ID:
MG/SP/E: section [810]
EVO: section [3070]
2)
Enter the IP reporting account numbers (one for each partition):
MG/SP/E: section [918] / [919]
EVO: section [2976] to [2983]
3)
In the General IP Options section, set up IP line monitoring options and dialer options, and
ensure IP reporting is enabled (see the following tables).
LED
Description
User
On when a user is connected
Internet
LED Status
Internet Connection
ParadoxMyHome Enabled
On
Connected
Connected
Flashing
Connected
No connection
Off
No connection
No connection
LED Status
Internet Connection
ParadoxMyHome Disabled
On Connection
No
connection
Off
No connection
No connection
Link
Solid Yellow = Valid Link @ 10Mbp;
Solid Green = Valid Link @ 100Mbp;
LED will flash according to data traffic.
Flashing Yellow/Green = DHCP trouble.
Rx/Tx
On after first successful communication exchange;
Flashes when data is transmitted or received through/from panel;
Off when no connection has been established.
I/O 1
On when activated
I/O 2
On when activated
MG/SP/E: section [806]
EVO: section [2975]
4)
Enter the monitoring station’s IP address(es), IP port(s), receiver password(s), and security
profile(s) (information must be obtained from the monitoring station).
5)
Register the IP150 module with the monitoring station. To register, enter the sections below
and press [
ARM
]. The registration status is displayed as well as any registration errors.
NOTE: An IP150 used with an MG/SP/E system will always poll using the partition 1 IP account
number. When using an EVO system, the partition 1 IP account is used by default, but can be
defined in section [3020]. All reported system events will originate from the partition selected in
this section.
Remote Access
The IP150 provides remote access to control and monitor a security system via web browsers or
PC
software. This provides the user with the freedom to access the system from anywhere in the
world. The following steps will guide you in setting up remote access.
Step 1: Setting up the Router
This step allows you to set up the router so that the IP150 module can function properly.
1)
Ensure that the router is connected properly as indicated in the router’s instructions.
2)
Access your router’s configuration page. Refer to your router’s manual for the exact procedure.
In most cases, this is done by entering the router’s static IP address in the address bar of your
Web browser. For this instance, we will use 192.168.1.1 as an example.Your router’s IP address
IP Line Monitoring Options
[5]
[6]
Off
Off
Disabled
Off
On
When disarmed: Trouble only
When armed: Trouble only
On
Off
When disarmed: Trouble only
When armed: Audible alarm
On
On
Silent alarm becomes audible alarm
OFF
ON
[7]
Use dialer reporting
(telephone)
As backup for IP/
GPRS reporting
In addition to IP
reporting
[8]
IP/GPRS reporting
Disabled
Enabled
IP Line Monitoring Options
[5]
[6]
Off
Off
Disabled
Off
on
When disarmed: Trouble only
When armed: Audible alarm
On
Off
When disarmed: Trouble only (default)
When armed: Trouble only
On
On
Silent alarm becomes audible alarm
OFF
ON
[7]
Use dialer reporting
(telephone)
As backup for IP/
GPRS reporting
In addition to IP
reporting
[8]
IP/GPRS reporting
Disabled
Enabled
MG/SP/E Sections
IP Receiver
#1
#2
Backup
IP Address1
[929]
[936]
[943]
IP Port1
[930]
[937]
[944]
IP Address2
[931]
[938]
[945]
IP Port2
[932]
[939]
[946]
IP Password
[933]
[940]
[947]
IP Profile
[934]
[941]
[948]
EVO Sections
IP Receiver #1
#2
#3
#4
IP Address1 [2984] [2986]
[2988] [2990]
IP Port1
IP Address2
IP Port2
IP Password
IP Profile
MG/SP/E Registration
IP Receiver #
#1
#2
Backup
Register/Status
[935] [942] [949]
EVO Registration
IP Receiver #
#1
#2
#3
#4
Register/Status
[2985]
[2987]
[2989]
[2991]