Paradox IP150 Скачать руководство пользователя страница 2

IP150-EI04 07/2019

PARADOX.COM

Figure 4 - DHCP Settings

If DHCP is enabled

, verify that the IP address range leaves at least one IP address available outside of 

the range. The range shown in the above example would leave addresses 2 to 4 and 101 to 254 available 
(all the numbers in an IP address are between 1 and 254). Record one of the addresses outside the 
DHCP range as the one you will use for the IP150. 

If DHCP is disabled

, the IP150 will use the default 

address of 192.168.1.250. It is possible to change that address if needed using the Paradox IP Exploring 
Tools software.
4) In the router’s configuration page, go to the Port Range Forwarding section (also known as “port 

mapping” or “port redirection”).

 

Add a service/item, set the Port to 80 and enter the static IP address 

selected in the previous step for the IP module. If port 80 is already used, you can use another one, 
such as 81 or 82 but you will have to modify the IP150’s settings in step 2. Some Internet Service 
Providers block port 80, therefore the IP150 may function locally using port 80 but not over the 
Internet. If this is the case, change the port to another number. Repeat this step for port 10 000 
(screenshot below may differ depending on type of router used). Also, repeat this step for port 443 if 
using a secure connection (https).

Figure 5 - Port Range Forwarding

Step 2: Configuring the IP150

1) Using a computer connected to the same network as the IP150, open the Paradox IP Exploring Tools.
2) Click 

Find It

. Your IP150 appears in the list.

Figure 6 -  IP Exploring Tools

3) Right-click your IP150 and select 

Module setup

, refer to screen shot below. Enter the static IP 

address you recorded in Step 1.3 or modify the address so that it corresponds to the one you have 
selected for the IP150. Enter the IP150’s password (default: paradox) and click 

OK

. If it indicates that 

the IP address is already used, change it to another and modify it in the Port Forwarding of the router 
(Step 1.4) and go back to Step 2.1.

4) Set any additional information such as port, subnet mask, etc. To find this information, click 

Start > 

Programs > Accessories > Command Prompt

. Enter command: IPCONFIG /ALL (with space after 

IPCONFIG).

NOTE

: For increased communication security, please change the default PC password and Panel ID in 

the control panel. Also, note that the IP150 supports SMTP/ESMTP/SSL/TLS protocols.

Figure 7 -  Module Setup

Step 3: Using a Web Browser to Access the System

Once the module is configured, it can be accessed either from the local network or through the internet 
using the alarm system’s master code. 

On-Site Access:
1) Enter the IP address assigned to the IP150 in the address bar of your Web browser. If you have used 

a port other than port 80, you must add [: port number] at the end. (For example, if the port used is 81, 
the IP address entered should look like this: http://192.168.1.250:81). For a secure connection, make 
sure to write “https://...etc.”.

or

Use the Paradox IP Exploring Tools software, click 

Refresh

 and double-click on your 

IP150

 in the list.

2) Enter your alarm system’s 

User Code

.

 WARNING

: A pop-up warning you that the website’s certificate is not secure may occur. This is 

acceptable, click to continue.

Inputs and Outputs Connections

To configure your I/O terminals please refer to the IP150 Programming Guide. Refer to figures 8 and 9 for 
examples of input and output connections.

Technical Specifications

The following table provides a listing of the technical specifications for the IP150 Internet Module.

Figure 8 - Input Connection Example

Figure 9 - Output Connection Example

Specification

Description

Panel 
Compatibility

Any Digiplex EVO panel (V2.02 for IP reporting)
Any Spectra SP series panel (V3.42 for IP reporting)
Any MG5000 / MG5050 panel (V4.0 for IP reporting)

Encryption

AES 256-bit, MD5 and RC4

Current 
Consumption

100mA

Input Voltage

13.8VDC, supplied by the panel serial port

Enclosure 
Dimensions

10.9cm x 2.7cm x 2.2cm (4.3in x 1.1in x 0.9in) 

Approvals

CE, EN 50136-1, EN 50136-2 SP5, EN 50131-10 Grade 3, Class II

Warranty

For complete warranty information on this product, please refer to the Limited Warranty Statement found on the Web site 
www.paradox.com/Terms. or contact your local distributor. Specifications may change without prior notice. 

Patents

US, Canadian and international patents may apply. Paradox is a trademark or registered 
trademarks

 

of Paradox Security Systems (Bahamas) Ltd. © 2019 Paradox Security Systems 

(Bahamas) Ltd. All rights reserved. www.paradox.com