ACM24D - page 4
Door Output Power Selection Jumper
LED Feedback
Bi-directional Locate Feature
Pressing the locate button will initiate the Module Locate feature. When a Module Locate is initiated, the module’s representation in the BabyWare
software will flash and the module’s BUS, RX and TX LEDs will flash at 1Hz to indicate that it is in locate mode. A module locate can also be intiated from
the BabyWare software. From BabyWare right-click the module’s representation and select Locate Physical. The module’s BUS, RX and TX LEDs will
flash. We highly recommend that after pressing locate and identifying the module, open the programming page and assign the proper physical location
label and the doors’ labels and locations. After complete connection, use the space provided on the module to indicate the doors’ description.
Remote Firmware Upgrade
The ACM24D is firmware upgradeable remotely via the V32 controller’s RS485 Access bus at 57.6Kbps. Using BabyWare connect to the V32 account,
then right-click the desired module and select Upgrade. A firmware upgrade for a single module or group of modules will take usually less than 10 minutes.
J2 ON
Internal Power (12Vdc)
After lock activation, the
ACM24D goes into energy
save mode and reduces the
voltage.
J2 OFF External Power (AC/DC)
*
J2 ON
12Vdc fail
secure latch
(N.O.)
* 1N4007 Diode
Cathode to + voltage
Anode to - voltage
~
~
Power Supply
24Vac
Internal Power
Supply
Jumper
To COM of relays
COM
* Do not use a diode with AC power
Remove J2 jumper before
supplying external power.
J2 OFF
24Vac latch
(N.O.)
24Vac latch
(N.O.)
*
*
AC
Green on = AC or DC power supplied
CHRG
Green on = Battery low or charging
Green on < 4sec. = Battery test
BUS
RX
TX
STATUS
Blue
on
Green
flash
Green
flash
OK (communication in
progress)
Blue
flash
-
-
Firmware upgrade in
progress
Red
on
-
-
No communication
with V32
Red
flash
Green
flash
Green
flash
Module locate mode
DOOR 1 / DOOR 2
Green on = Door unlocked
Red on = Door locked
READER IN/OUT
Green on = Reader OK
Red on = Reader not assigned
Red flash = Reader missing
Off = No reader programmed
Patents
: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and other pending patents
may apply. Canadian and international patents may also apply.
Trademarks
: Paradox Imperial, MAMA, BabyWare, the M logo, and the triangle logo are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in Canada, the United
States and/or other countries.
Certification
: For the latest information on products approvals, such as UL and CE, please visit www.paradox.com.
Warranty
: For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. Your use of the Paradox product signifies your
acceptance of all warranty terms and conditions.
© 2009 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice.
PARADOX.COM
Printed in Canada - 03/2009 IACM24-EI00