48
EVOHD+ Installation Guide
Disarm Reporting Options
(default =
disabled)
When disabled, the control panel sends the Disarming Report Codes (page 40) every time the partition is disarmed. When enabled, the control
panel sends the Disarming Report Codes to the monitoring station only when the partition is disarmed following an alarm. Select the section that corresponds to
the desired partition and enable or disable option
[7]
:
Zone Restore Report Options
S
ECTION
[3037]: O
PTION
[8]
(default =
disabled
) When disabled, the control panel sends the
Zone Alarm Restore
report codes to the monitoring station when the Bell Cut-Off Timer elapses or
when the alarm is disarmed. When enabled, the control panel sends the
Zone Alarm Restore
report codes (see section ) to the monitoring station as soon as the zone
returns to normal (zone closure) or upon disarming.
Auto Report Code Programming
When using either the Contact ID or SIA Reporting Formats (see section on page 45), the control panel can automatically program a set of default report codes. The
Contact ID Reporting Format can be modified using the manual programming method (see page 46) to program remaining report codes or to change some of the
defaults. Enter any of the following sections to set the indicated report codes with the default values (FF) from the
Automatic Report Codes List
in the "EVOHD+
Programming Guide":
Closing Delinquency Timer
(default =
000
; disabled) When a partition in the system is disarmed, the control panel will start the corresponding partition’s Closing Delinquency Timer. If the
Closing Delinquency Timer elapses before the partition is armed again, EVOHD+ will transmit a “Closing Delinquency” report code to the monitoring station. Enter
a value from 001 to 255 days into the appropriate section. Enter 000 to disable the Closing Delinquency Timer.
Partition 1:
[3123]
Partition 3:
[3323]
Partition 5:
[3523]
Partition 7:
[3723]
Partition 2:
[3223]
Partition 4:
[3423]
Partition 6:
[3623]
Partition 8:
[3823]
Section
Description
[4030]
Resets all the report code sections to 00 (cleared).
[4031]
Sets all the report code sections to FF (defaults).
Section
Sets to Defaults (FF)
Reset Sections
[4032]
Zone Alarm and Restore Report Codes
Tamper and Restore Report Codes
[0201]
to
[0296]
[4033]
Keyswitch Arming Report Codes
Keyswitch Disarming Report Codes
Access Code Arming Report Codes
Access Code Disarming Report Codes
[0701]
to
[0732]
[0801]
to
[0832]
[2001]
to
[2099]
[2101]
to
[2199]
[4034]
Special System Report Codes
[3900]
to
[3909]
[4035]
Special Arming Report Codes
Special Disarming Report Codes
[3910]
to
[3919]
[3920]
to
[3929]
[4036]
Special Alarm Report Codes
[3930]
to
[3939]
[4037]
Trouble and Restore Report Codes
[3940]
to
[3991]
Partition 1:
[3119]
Partition 3:
[3319]
Partition 5:
[3519]
Partition 7:
[3719]
Partition 2:
[3219]
Partition 4:
[3419]
Partition 6:
[3619]
Partition 8:
[3819]