EVOHD+ Installation Guide
45
Monitoring Station Phone Number
S
ECTIONS
[3071]
TO
[3074]
The control panel can dial up to 4 different monitoring station telephone numbers. Sections
[3071]
to
[3074]
represent monitoring station telephone numbers 1
through 4. Enter any digit up to a maximum of 32.
Table 5: Special Telephone Number Keys
Account Number
S
ECTIONS
[3061]
TO
[3068]
(default =
000
) All report codes are preceded by a 3- or 4-digit Account Number to ensure correct identification of system events. Account Numbers can be any
hexadecimal value from 0 to F.
NOTE:
Only the SIA format supports the [0] = 0 digit in its account numbers. Account numbers that use other reporting formats do not support the [0] = 0 digit.
Enter the [STAY] = A digit in its place. When using the SIA Format, and the Account Number Transmission (see section on page 45) corresponds to the partition, the
control panel only uses the Partition 1 Account Number programmed in section
[3061]
, but the report code includes the partition number.
Account Number Transmission
S
ECTION
[3035]: O
PTION
[6]
(default =
Partition Account #
) When enabled, the account number corresponding to the MSTN that was dialed will be sent regardless of which partition the report
originated from. When disabled, the account number that is sent to the monitoring station corresponds to the partition where the event originated, regardless of
which MSTN is dialed.
Reporting Formats
S
ECTION
[3070]
The control panel can use a number of different reporting formats. Each monitoring station phone numbers should be programmed with the same reporting
format. The first digit represents the reporting format (see Table 7) used for Monitoring Station Telephone Number 1, the second digit, Monitoring Station
Telephone Number 2, etc.
Table 7: Reporting Formats*
* UL Note:
Installer must verify the compatibility with of the DACR. Use listed compatible DACRs.
Functions
Key
*
[
STAY
]
[#]
(Press the key until the
desired letter/symbol
appears)
#
[
FORCE
]
Switch to Tone Dialing (T)
[
ARM
]
Wait for second dial tone (W)
[
DISARM
]
4-second pause (P)
[
BYP
]
Insert
[
MEM
]
—
Delete
[
TRBL
]
—
Delete from cursor to end
[
ACC
]
Left action key (
Clear
)
Table 6: Account Numbers
Section
Account Number
Section [3035], option
[6] = disabled
Section [3035], option
[6] = enabled
[3061]
Account Number 1
Partition 1
MSTN 1
[3062]
Account Number 2
Partition 2
MSTN 2
[3063]
Account Number 3
Partition 3
MSTN 3
[3064]
Account Number 4
Partition 4
MSTN 4
[3065]
Account Number 5
Partition 5
N/A
[3066]
Account Number 6
Partition 6
N/A
[3067]
Account Number 7
Partition 7
N/A
[3068]
Account Number 8
Partition 8
N/A
Compatible Digital Alarm Communication Receivers (DACRs):*
Sur-Gard DRL2A
Ademco 685
Osborne Hoffman Quick Alert II
0
= Ademco slow (1400Hz, 1900Hz, 10BPS)
4
= N/A
1
= Silent Knight fast (1400Hz, 1900Hz, 20BPS)
5
= Ademco Contact ID
2
= Sescoa (2300Hz, 1800Hz, 20BPS)
6
= SIA FSK
3
= Ademco Express (DTMF 4+2)
7
= N/A