background image

Streamline

section

Data

Description

Address

___/___
___/___

/

___/___

___ ___

Future use
1st digit: value must be entered i.e.
2nd digit: time correction (See table)
1st digit: telephone 1 format
2nd digit: telephone 2 format
1st digit: PGM 1 type
2nd digit: PGM 2 type

[2

]

ND

036
037

038

039

09

PGM 1
PGM 2
PGM mask 1
PGM mask 2

040
041
042
043

___/___
___/___

/

___/___

___ ___

10

TIME CORRECTION:

(address 037 second digit)

[2

]

[1]
[2]
[3]
[4]
[5]
[6]
[7]

ND

- No adjustment
- Plus    4 sec.
- Plus    8 sec.
- Plus  12 sec.
- Plus  16 sec.
- Plus  20 sec.
- Plus  24 sec.
- Plus  28 sec.

[8]
[9]
[10]
[11]
[12]
[

]

[

]

[

]

- Minus    4 sec.
- Minus    8 sec.
- Minus  12 sec.

- Minus  16 sec.
- Minus  20 sec.
- Minus  24 sec.
- Minus  28 sec.

- Minus  32 sec.

BYP

MEM

TRBL

COMMUNICATOR FORMATS

Key

[2

]

[1]
[2]
[3]
[4]
[5]

ND

[6]
[7]
[8]
[9]

[10]

[

]

TRBL

=

slow (1400Hz, 1900Hz, 10bps)

= (1400Hz, 1800Hz, 10bps)
=

fast (1400Hz, 1900Hz, 20bps)

=

(2300Hz, 1800Hz, 20bps)

=                      (40bps with 1400Hz handshake)
=                      (40bps with 2300Hz handshake)

ADEMCO

SILENT KNIGHT
SESCOA
RADIONICS
RADIONICS

=                      with PARITY (1400Hz, 40bps)
=                      with PARITY (2300Hz, 40bps)
=

express

=

contact ID (programmable codes)

=

contact ID (all codes)

=

- no handshake (personal dialing)

RADIONICS
RADIONICS
ADEMCO
ADEMCO
ADEMCO
DTMF

[2    ]

ND

- 3 -

PG748EX

For addresses

to

, see pages 7 to 10.

044

126

CID

100:
110:
111:
112:
113
114:
115:
116:
117:
118:
120:
121:
122:
123:
130:
131:
132:
133:
136:
137:
138:
140:
150:
151:
152:
153:
154:
155:
156:
157:
158:
159:
161:

CID

300:
301:
302
305:
306:
309:
320:
321:
323:
350:
351:
354:
370:
371:
372:
373:
382:
383:
400:
401:
402:
403:
404:
407:
410:
441:
570:
572:
573:
574:
601:
602:
625:

P

ROG. VALUE

[2

]

[2

]

[2

]

[2

]

[2

]

[2

]

[2

]

[2

]

[2

]

[2

]

[2

]

[2

]

[2

]

[

]

[2

]

[

]

[2

]

[

]

[2

]

[

]

[

]

[

]

[2

]

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

ND

BYP

ND

MEM

ND

TRBL

ND

BYP

MEM

TRBL

ND

/ [1]
/ [2]
/ [3]
/ [4]
/ [5]
/ [6]
/ [7]
/ [8]
/ [9]
/ [10]
/ [11]
/ [12]
/
/
/

[1] /
[1] / [1]
[1] / [2]
[1] / [3]
[1] / [4]
[1] / [5]
[1] / [6]
[1] / [7]
[1] / [8]
[1] / [9]
[1] / [10]
[1] / [11]
[1] / [12]
[1] /
[1] /
[1] /
[2] /
[2] / [1]

P

ROG. VALUE

[2] / [2]
[2] / [3]
[2] / [4]
[2] / [5]
[2] / [6]
[2] / [7]
[2] / [8]
[2] / [9]
[2] / [10]
[2] / [11]
[2] / [12]
[2] [

]

[2] [

]

[2] [

]

[3] / [2

]

[3] / [1]
[3] / [2]
[3] / [3]
[3] / [4]
[3] / [5]
[3] / [6]
[3] / [7]
[3] / [8]
[3] / [9]
[3] / [10]
[3] / [11]
[3] / [12]
[3] [

]

[3] [

]

[3] [

]

[4] / [2

]

[4] / [1]
[4] / [2]

/
/
/

/
/
/

BYP

MEM

TRBL

ND

BYP

MEM

TRBL

ND

R

EPORTING CODE

MEDICAL
FIRE ALARM
FIRE SMOKE
COMBUSTION
WATER FLOW
HEAT
PULLSTATION
DUCT
FLAME
NEAR ALARM
PANIC ALARM
DURESS
SILENT PANIC
AUDIBLE PANIC
BURGLARY
PERIMETER BURG.
INTERIOR BURG.
24HR BURGLARY
BURGLARY OUTDOOR
BURGLARY TAMPER
BURGLARY NEAR ALARM
GENERAL ALARM
24 HOUR AUX
GAS DETECTED
REFRIGERATION
LOSS OF HEAT
WATER LEAKAGE
FOIL BREAK ALARM
DAY TROUBLE ALARM
LOW GAS LEVEL
HIGH TEMPERATURE
LOW TEMPERATURE
LOSS AIR FLOW

R

EPORTING CODE

SYSTEM TROUBLE
AC LOSS
LOW SYSTEM BATTERY
SYSTEM RESET
PROGRAM CHANGED
BATTERY TEST FAIL
SOUNDER/RELAY TROUBLE
BELL 1 TROUBLE
ALARM RELAY TROUBLE
COMMUNICATION TROUBLE
TELCO 1 FAULT
FAIL TO COMMUNICATE
PROTECTION LOOP TROUBLE
PROTECTION LOOP OPEN
PROTECTION LOOP SHORT
FIRE LOOP TROUBLE
SENSOR TROUBLE
SENSOR TAMPER
OPEN/CLOSE
OPEN/CLOSE BY USER #
GROUP OPEN/CLOSE
AUTOMATIC OPENING/CLOSING
LATE TO OPEN/CLOSE
REMOTE ARM DOWNLOAD
REMOTE ACCESS
OPEN/CLOSE - STAY MODE
BYPASS
24 HOUR ZONE BYPASS
BURGLARY BYPASS #
GROUP BYPASS
MANUAL TEST
PERIODIC TEST
TIME/DATE RESET

PROGRAMMABLE CONTACT ID EVENT CODES

All addresses from        to        (sections

to     ) programmed with values other than

will report the contact

ID codes corresponding to the values programmed. Values to be programmed should be selected from this table.

300     523

11     66

[2

] [2

]

ND

ND

Содержание Esprit 748 Express

Страница 1: ...SECTION PROGRAMMING Can be used to program sections 00 to 66 addresses 000 to 043 and 300 to 523 Press ENTER installer code and 7 2ND and ENTER keys alternately flash Enter a 2 digit section number followed by 8 digits to program that section confirmation beep Data will be saved automatically and the software advances to the next programming section To exit programming mode press CLEAR INSTALLER C...

Страница 2: ...NTRAL STATION TELEPHONE NUMBER 2 View at addresses 024 to 031 06 __ __ __ __ __ __ __ __ 07 __ __ __ __ __ __ __ __ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ACCOUNT A AND B View at addresses 032 to 035 08 ___ ___ ___ ___ ___ ___ ___ ___ 1 2 3 4 5 6 7 8 A B If only one account number is required the same number must be entered for both account A and B 2 PG748EX Press TRBL to end phone number if less ...

Страница 3: ... 2 2 2 2 2 2 2 2 2 2 2 2 2 2 ND ND ND ND ND ND ND ND ND ND ND ND ND BYP ND MEM ND TRBL ND BYP MEM TRBL ND 1 2 3 4 5 6 7 8 9 10 11 12 1 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 1 1 2 2 1 PROG VALUE 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 2 11 2 12 2 2 2 3 2 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 10 3 11 3 12 3 3 3 4 2 4 1 4 2 BYP MEM TRBL ND BYP MEM TRBL ND REPORTING CODE MEDICAL FIRE ALARM...

Страница 4: ..._ ___ ___ _ ___ ___ ___ __ User code 27 User code 28 User code 29 User code 30 328 329 330 331 12 18 User code 7 User code 8 User code 9 User code 10 User code 15 User code 16 User code 17 User code 18 308 309 310 311 316 317 318 319 User code 31 User code 32 User code 33 User code 34 User code 39 User code 40 User code 41 User code 42 332 333 334 335 340 341 342 343 ___ ___ ___ ___ ___ ___ ___ __...

Страница 5: ...r code 10 User code 11 User code 12 User code 17 User code 18 User code 19 User code 20 360 361 362 363 368 369 370 371 26 28 User code 33 User code 34 User code 35 User code 36 User code 41 User code 42 User code 43 User code 44 User code 45 User code 46 User code 47 User code 48 384 385 386 387 392 393 394 395 396 397 398 399 ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ __...

Страница 6: ...ne 9 Zone 10 Zone 11 Zone 12 432 433 434 435 456 457 458 459 N A N A N A N A N A N A N A N A 440 441 442 443 464 465 466 467 ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ 44 50 46 52 N A N A N A N A N A N A N A N A 444 445 446 447 468 469 470 471 ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ 47 53 Z...

Страница 7: ...t value will be displayed on keypad 4 Enter 3 digit DECIMAL value 5 Repeat from step 2 onward for next address To exit programming mode press CLEAR 044 ___ ___ ___ hours Auto arm time between 000 and 023 045 ___ ___ ___ minutes Auto arm time between 000 and 059 046 ___ ___ ___ days Auto test report every days between 001 and 255 000 disabled 047 ___ ___ ___ hours Auto test report between 000 and 0...

Страница 8: ...econds and 129 to 255 for minutes factory default 5 seconds Add 128 to desired value in minutes i e for 5 minutes enter 5 128 133 057 ___ ___ ___ Intellizone delay in seconds minimum 10 seconds factory default 48 seconds 058 ___ ___ ___ Installer code lock 147 locked 000 unlocked 059 ___ ___ ___ seconds Programmable delay before alarm transmission 5 to 63 seconds 000 disabled 060 ___ ___ ___ secon...

Страница 9: ...ENCE tel No TYPE 11 12 1 2 1 2 1 2 1 2 fail to comm 1 1 1 1 1 1 1 1 fail to comm 2 2 2 2 2 2 2 2 fail to comm 1 1 1 1 1 1 1 1 fail to comm 2 2 2 2 2 2 2 2 fail to comm On alarm all reports are made to Tel 1 until system is disarmed Once disarmed system reports are made to Tel 2 Address 086 Key 11 12 N A N A 090 Exclude power failure from trouble display 2 ND OFF ON 3 1 enabled 2 stay System A Auto...

Страница 10: ...nel time and clear trouble 8 all 3 codes Key MEM flashes Enter two digits 00 to 23 for hours 2 digits 00 to 59 for minutes BYP Test report all 3 codes Reporting is enabled at address 086 keys 11 12 A value must be entered at address 512 and both telephone and account numbers must be programmed TRBL Call Espload via telephone all 3 codes Panel identifier and PC password addresses 004 007 and comput...

Страница 11: ...et address 090 key 8 off N C and or N O contacts see Figure 2 ZONE connection with tamper recognition N C contacts address 088 key MEM on key 10 key 11 address 090 key 8 off Tamper transmits separate code see Figure 3 ZONE connection with EOL with tamper recognition and with wire fault short circuit recognition N C contacts address 088 key MEM off key 10 key 11 address 090 key 8 off Tamper wire fa...

Страница 12: ...vision must be OFF PS1 software versions onward Keypad software versions onward 2 0 4 0 Keypad supervision must be ON See Address key 090 11 12 FIRE RESET To program PGM1 to conduct 4 second smoke detector reset when and are pressed simultaneously CLEAR ENTER Address first digit Address 039 040 5 10 BYP Address Address 042 2 6 056 10 10 4 ND FIRE ALARM ZONE CONNECTIONS PGM maximum 50mA Smoke detec...

Отзывы: