642
5
Keypad Zone
Section
[2]
— Option
[1]
Off
= Disabled
On
= Enabled (default)
This option enables/disables the keypad’s on-board zone. Only two
keypad zones are available on an Esprit control panel, and only one
on-board zone per keypad.
Keypad Zone Requires 1k
Ω
EOL Resistor
Section
[2]
— Option
[2]
Off
= No (default)
On
= Yes
When option [2] is off, you do not need to install an EOL resistor.
When option [2] is on, you must install an external 1k
Ω
EOL resistor
as shown in Figure 1 on page 29.
Keypad Zone Set To Zone 1/Zone 2
Section
[2]
— Option
[3]
Off
= Keypad Zone 1 (default)
On
= Keypad Zone 2
The Esprit system supports two keypad zones, and this option
determines whether the on-board keypad zone input is identified as
keypad zone 1 or keypad zone 2.
Keypad Communication Supervision
Section
[2]
— Option
[4]
Off
= Disabled (default)
On
= Enabled
Enable this option to monitor the communication between the control
panel and the keypad. If there is a loss of communication with the
keypad, the control panel generates an open keypad zone. This