Digiplex EVO • Programming Guide
Version 7.11
Additional Settings and Modes | 59
Software Reset
To set specific software parameters back to their initial, default values, proceed as follows:
1.
Enter programming mode (refer to
Entering Programming Mode on page 3
for details).
2.
Enter section
[4049]
to unlock the software reset function.
3.
Enter the four-digit section corresponding to the software reset you wish to perform.
If you want to reset more than one section, enter section
[4049]
to unlock the software reset function once again.
Installer Function Keys
To access the installer functions, press and hold
0
, enter the installer code, and then:
•
For keypads K641R/K641LX/K641+
and K656: press the key indicated in
, that corresponds to the function you wish to activate.
Table 56: Description of Software Reset Sections ([4040] to [4049])
Section Description
[4040]
Entering this section will reset all programmable sections, from
[0001]
to
[3999]
, to their factory default values.
[4041]
Entering this section will reset the system master code to 123456.
[4042]
Entering this section will reset all zone programming, including sections
[0961]
to
[0984]
, to their default values.
[4043]
Entering this section will reset all access control sections, from
[2201]
to
[2712]
(excluding door labels), to their default values.
[4044]
Entering this section will reset all user code sections, from
[1001]
to
[1999]
and
[2001]
to
[2199]
, to their default values.
[4045]
Entering this section will reset programming of all dialer sections (
[3051]
to
[3081]
), VDMP3 sections (
[3087]
to
[3098]
), and control panel sections
(
[3020]
to
[3043]
and
[3900]
to
[3991]
), to their default values.
[4046]
Entering this section will reset all partition sections, from
[3101]
to
[3833]
(excluding partition labels), to their default values.
[4047]
Entering this section will reset programming of all PGM sections (
[0901]
to
[0959]
) and all keyswitch sections (
[0501]
to
[0632]
), as well as all keyswitch
arming/disarming report code sections (
[0701]
to
[0832]
), to their default values.
[4048]
Entering this section will clear all user labels, door labels, partition labels, module labels, and zone labels, from sections
[0301]
to
[0396]
.
[4049]
Entering this section will unlock software reset for sections
[4040]
to
[4048]
.
Table 57: Description of Installer Functions for the K641R/K641LX/K641+ and K656 Keypads
Function
Description
K641R/
K641LX/
K641+
K656
Test report
Sends the
Test Report
report code programmed in section
[3902]
, to the monitoring station.
STAY
STAY
Call BabyWare software
Will dial the PC telephone number programmed in section
[3010]
, to initiate communication with a
computer using the BabyWare software.
FORCE
SLEEP
Answer BabyWare
software
Will force the control panel to answer a call made by the monitoring station, which is using the
BabyWare software.
ARM
ARM
Cancel communication
Cancels all communication with the BabyWare software or with the monitoring station, until the next
reportable event.
DISARM
OFF
Installer test mode
This mode allows you to perform walk tests, where the bell or siren will squawk to indicate opened
zones.
To exit, press
MEM
(for K641R/K641LX/
K641+
) or (for K656). Partitions cannot be armed if the
installer test mode is enabled.
MEM
Start module scan
The keypad will display the serial number of each module on the combus.
TRBL
/TBL
Combus voltmeter
To verify if the combus is supplying sufficient power, press and hold
0
, enter the installer code, and
press either
ACC
or , depending on the type of keypad. A reading of 12.3V or lower, at the panel’s
service keypad connector, indicates that the voltage is too low. The voltage may drop during the
control panel battery test.
ACC