16
System Events
All Digiplex system events are sent through the Printer Module to the home automation module using the following format.
* xxx represents the 3-digit event group (G).
** yyy represents the 3-digit event number (N).
*** zzz represents the 3-digit area number (A). Area number 000 signifies that the event has occurred in all enabled areas or is a global
event independent of area assignment.
As shown above, system events involve a 3-digit event group (Gxxx), a 3-digit event number (Nyyy) and a 3-digit area number (Azzz). The
following table lists the event group and event number descriptors that can be used to read the system event format. For example,
G001N005A006 means zone 5 in area 6 has been opened. (Event group 001= Zone open, Event number 005= zone 5, Area 006= area 6).
Byte 1
Bytes 2-4
Byte 5
Bytes 6-8
Byte 9
Bytes 10-12
System Event
G
xxx*
N
yyy**
A
zzz***
Event
Group (G)
Event Group Description
Event Number (N)
Event Number Description
Area Number (A)
000
Zone is OK
001-096
Zone Numbers
001-008
001
Zone is Open
002
Zone is Tampered
003
Zone is in Fire Loop Trouble
004
Non-reportable Event
000
TLM Trouble
000-008
001
Smoke detector reset
002
Arm with no entry delay
003
Arm in Stay mode
004
Arm in Away mode
005
Full arm when in Stay mode
006
Voice module access
007
Remote control access
008
PC Fail to communicate
009
Midnight
010
NEware User Login
011
NEware User Logout
012
User Initiated Callup
013
Force Answer
014
Force Hangup
005
User Code entered on
Keypad
000-999
User Codes
000-008
006
User/Card Access on door
001-032
Door Numbers
000-008
007
Bypass Programming
Access
000
One-touch Bypass Programming
001-008
001-999
User Code
008
TX Delay Zone Alarm
001-096
Zone Numbers
001-008
009
Arming with Master
001-999
User Codes
001-008
010
Arming with User Code
001-999
User Codes
001-008
011
Arming with Keyswitch
001-032
Keyswitch numbers