Digiplex LED Keypad 11
n
5.0 PGM Programming
5.1 PGM State
SECTION
[011]
OPTION
[1]
The keypad's on-board PGM can be set as normally open or
normally closed. When an open PGM is activated, it will close the
circuit to the ground and enable any devices connected to it. When a
closed PGM is activated, it will open the circuit and disable any
devices connected to it. When the PGM Activation Event occurs (see
section 5.2), the PGM will switch to its opposite state (i.e. open to
closed or closed to open). The PGM is limited to 50mA.
Option
[5]
OFF = PGM is Normally Open (default).
Option
[5]
ON = PGM is Normally Closed.
5.2 PGM Activation Event
SECTION
[014]
to
[017]
Modules belonging to the DGP2 series are programmed using the
PGM Programming table in the
Digiplex/DigiplexNE Modules’
Programming Guide
. The PGM Activation Event determines which
event will activate the keypad's on-board PGM output. The
EVENT
GROUP
specifies the event, the
FEATURE
GROUP
identifies the source,
and the
START
#
and
END
#
sets the range within the Feature Group.
Use the PGM Programming Table in the
Digiplex/DigiplexNE
Modules’ Programming Guide
to program the keypad’s PGM
deactivation Event.
Enter the sections that correspond to the
EVENT
GROUP
,
FEATURE
GROUP
,
START
#
and
END
#
of the PGM and enter the required data.
Event group
Feature group
Start #
End #
PGM
[014]
[015]
[016]
[017]
DGP2648_EI06.fm Page 11 Thursday, July 22, 2004 9:15 AM