DCT10-EI08 10/2015
DCT10 V3.0
PARADOX.COM
Dual Anti-Tamper
The DCT10 offers dual anti-tamper protection against the opening of the unit’s cover or the removal of the unit from the mounting location.
Secure the anti-tamper pin to the wall using the supplied screw. In the case where the unit is forcibly removed, the anti-tamper pin breaks away
from the rest of the unit, triggering a tamper alarm.
If the unit is installed on a drywall surface, use a drywall anchor to secure the anti-tamper pin.
Powering the unit
Verify proper polarity and insert two alkaline “AAA” batteries. After inserting batteries, a power up sequence will begin (10-20 seconds) during
which the door contact will not detect an open zone or tamper.
Low Battery
The DCT10 performs a battery test every 12 hours. If the voltage is below 2.3V after four consecutive battery tests (48 hrs.), the red LED will flash at
5 second intervals and the DCT10 will transmit a low battery signal (Optional for EN 50131 Grade 2).
Battery Replacement
To replace batteries:
1) Replace the old batteries with new ones.
2) Press and release the anti-tamper switch several times.
3) Wait 60 seconds to re-initialize the unit.
Technical Specifications
For complete warranty information, please visit www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all warranty terms and conditions. Magellan is a
trademark or registered trademarks of Paradox Security Systems (Bahamas) Ltd. or its affiliates in Canada, the United States and/or other countries. For the latest product approvals, such as
UL and CE, please visit www.paradox.com. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 7046142, 6215399,
6111256, 6104319, 5920259, 5886632, 5721542, 5287111, and RE39406 and other pending patents may apply. Canadian and international patents may also apply. Changes or
modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. © 2015 Paradox Security Systems (Bahamas) Ltd.
Reed switch w/magnet
Two (high sensitivity) with a standard gap of 1cm (0.4”) from magnet
Input Response Time
45 ms
RF frequency
433MHz or 868MHz
Power
3 Vdc (Two “AAA” Alkaline batteries)
Battery life
Up to three years
Range (typical in a
residential environment)
MG5000/MG5050/RTX3: 70m (230ft)
Current Consumption
2.5µA @ Standby. 0.87mA @ Alarm
Removal Distance
30mm
Approach Distance
10mm
Anti-tamper switch
Dual
Compatibility
Magellan Protocol: MG5000, MG5050, RTX3, and RX1
Dimensions
12.5 x 4.6cm x 2.5 cm (4.9 x 1.8 x 1.0in)
Operating temperature
5°C to 40°C (32°F to 120°F)
Certifications
EN 50131-2-6 Grade 2 Class I. Certification body: ANPI ASBL
Anti-tamper