Digiplex & DigiplexNE
- 1 -
Module
s
Programming Guide
4-zone Expansion Module
* For the Base Time, using Level Programming (refer to page 1), press
the
and
buttons to select a value from 000 to 002 and then press
[
ENTER
]
. Base Time Multipliers: 000 = 15 ms, 001 = 1 second, 002 = 1 minute.
U
= Default setting
SECTION [001] : General Options
Option
OFF
ON
[1]
Tamper Recognition
ON = Input 4 (Z4) becomes tamper input
U
Disabled
N
Enabled
[2] to [8]
Future Use
N
N/A
N
N/A
Input Speed
Base Time (000-002)*
Time Value (000-255)
Default
Input 001
[002]
___/___/___
[003]
___/___/___
600ms
Input 002
[004]
___/___/___
[005]
___/___/___
600ms
Input 003
[006]
___/___/___
[007]
___/___/___
600ms
Input 004
[008]
___/___/___
[009]
___/___/___
600ms
Input 005 (ATZ of Input 001)
[010]
___/___/___
[011]
___/___/___
600ms
Input 006 (ATZ of Input 002)
[012]
___/___/___
[013]
___/___/___
600ms
Input 007 (ATZ of Input 003)
[014]
___/___/___
[015]
___/___/___
600ms
Input 008 (ATZ of Input 004)
[016]
___/___/___
[017]
___/___/___
600ms
APR3-ZX4