24 User’s Guide
Arming (see section 4.3).
Exit and Force Arm: Press and hold the [
FORCE
] button for 3
seconds (see Note2) to start the Exit Delay (see section 4.1).
When the Exit Delay elapses, the system will switch to Force
Arming (see section 4.5).
4.7.4 One-Touch Force Arming
Press and hold the [
FORCE
] button for 3 seconds (see Note2) to
bypass any open Force Zones. For details on Force Arming,
refer to section 4.5.
4.7.5 One-Touch Bypass Programming
Press and hold the [
BYP
] button for 3 seconds (see Note2) to
access Bypass Programming Mode (see section 4.6).
4.8 K
EYSWITCH
A
RMING
A keyswitch can be used to arm and disarm the system. A
keyswitch is assigned to and programmed to Stay Arm
(see section 4.4) or Regular Arm (see section 4.3) a
specific partition. A keyswitch can function as a Maintained
or Momentary keyswitch.
To arm the system using a Maintained Keyswitch, set the
keyswitch to the “on” position. To disarm the system set the
keyswitch to the “off” position.
To arm the system using a Momentary Keyswitch, set the
keyswitch to the “on” position then turn it back to the “off”
position. Repeating this sequence will disarm the system.