Figure 4
- MRTCP-IP module’s reset pins identification
Note: The MRTCP/IP module comes with the default
settings of pin “12345”, IP address 192.168.0.232
and incoming port 9999.
SmartView Software
Figure 5 -
SmartView software Units Observer screen
1. Open the
SmartView
software.
2. Select “Matrix Network Utility” at the Operations section.
3. A window will appear with the Matrix Network Utility main
screen (see Figure 2).
4. Follow the Matrix Network Utility instructions as mentioned
in the previous paragraph (Matrix Network Utility (MNU)).
Technical Characteristics
Power Supply
10 pin box connector
5 VDC / 12-24 VDC
Terminal Connector
12-24 VDC
Consumption
250mA MAX
Connections
Ethernet, Serial RS485
Ethernet
Ground isolation
Full galvanic isolation
Connector
RJ45
Ethernet type
10/100 Mbps
RS485
Max. distance for repeater
connection (twisted pair/
UDP)
200 meters
VBB/- output of 485 port
max. consumption
500mA
Attention! Confirm the ability to provide
of Matrix2000 panel this current
Indications
Power
Device is powered
Optioning
TERM
RS485 termination. Connects
120Ohm resistor with RS485 bus
General
Operating Temperature
From 0°C to 50°C (14°F to 122 °F)
Humidity
95% max.
Dimensions
7.4 x 9.7cm
MRTCP-IP module panel installation
The MRTCP-IP module installation at the panel, with the help
of the module’s metal base as shown in Figure 7.
1. Attach the MRTCP-IP module at the metal base.
2. Remove the two screws that hold the panel’s keypad as
indicated below (Figure 5). Place the base with the TCP-IP
module and replace the screws.
Figure 6 -
MRTCP-IP module’s placement
3.
WARNING:
Remove power from the Matrix2000 panel.
4. Connect the MRTCP-IP module to the Matrix2000 main
board using the flat cable provided and as shown in Figure 1.
Figure 7 -
MRTCP-IP module on panel
www.paradox.gr
Korintou 3, Metamorfosi 144 51, Athens-Greece
MRTCP-IP Module Quick Installation Guide / MRTCP-IPQI ver.1.0, rev.2