44
•
Troubleshooting
GXL-45 Operator Manual
Convert to Another Gas Type
The conversion process (orifice change-out) is the same for each gas. Whatever gas your grill is set for, it is
supplied with a conversion kit (Figure 39 left) to allow changeover to the other fuel type. The customer is
required to provide the LP gas inlet or NG regulator (4” water column, 1/2" ports).
Figure 39 Gas Conversion Kit
This procedure must be completed by a licensed plumber or gas professional.
Main Burners Conversion:
1.
Shut off and disconnect the gas source from the grill
2.
Remove all cooking grates and flame tamers to expose the main burners
3.
If needed, remove the cotter pins from the far end of each burner tube (see
4.
Lift the far end of a burner, slide the burner toward the rear of the grill, and lift upward; repeat to
remove each burner
Figure 40 Main Burner Orifice
5.
Use a shallow 6mm socket and handle to reach into the burner opening and carefully remove the
brass orifice screwed into the end of the valve stem (Figure 40);
brass fittings are fragile
6.
Replace the orifice with the change-out orifice;
brass fittings are fragile
and very little pressure is
needed for a secure connection; follow these precautions:
•
Use a shallow socket to ensure enough threads are exposed to get it started (Figure 39 right)