Convert to Another Gas Type
The conversion process (orifice change-out) is the same for each gas. Whatever gas your burner unit is set
up for, it is supplied with a conversion kit (Figure 24 left) to allow changeover to the other fuel type. The
customer must provide the required LP gas inlet or NG flex line.
Figure 24 Natural Gas Conversion Kit
This procedure must be completed by a licensed plumber or gas professional.
1.
Unplug the burner unit
2.
Shut off and disconnect the gas source from the burner unit
3.
Remove the cover and grate; set aside
4.
Lift the front burner out and set it near the rear burner
•
The igniter plug is attached to the burner knob
•
Do not pull on the cable enough to unplug the igniter
Figure 25 Remove Burner
5.
Use a shallow 6mm socket and handle to reach into the burner opening and carefully remove the
brass orifice screwed into the end of the valve stem (Figure 25)