P300H
P300 Modem Installation and Operating Handbook
Page 12
2.4
FEATURE HIGHLIGHT
This list highlights some of the notable features about the P300 Modems:
All P300 Modems (ie base modem features)
8
Variable data rate in 1 bps steps with fast acquisition even at low data rates
8
BPSK, QPSK, and Offset QPSK (OQPSK)
8
Viterbi FEC (to IESS 308/309), rate 1/2, 3/4 & 7/8 in BPSK, QPSK and OQPSK.
8
100Hz I.F. resolution
8
RS422, V.35, and RS232 DCE interface on both EIA 530 25 pin and RS449 37 pin connectors.
8
Can accommodate Viterbi & Sequential FEC simultaneously
8
Built in 1-FOR-1 Redundancy Controller (requires only cables, passive I.F. splitter/combiner &
second modem for complete 1:1 in just 2U)
8
0-99ms Doppler/plesiochronous buffer
8
Full remote M&C
8
1000 event traffic log, with facility to continuously log circuit performance at regular intervals (logs
average & worst case Eb/No and/or user BER)
8
`In The Rack` upload of revised internal software
8
25dB Tx I.F. level control in 0.1dB steps
8
Band limited I.F. input capable of operating with high composite power (ie I.F. input not `wide open`
and affected by out of band signals)
8
1PPM internal frequency & clock reference, with external station clock input
8
CCITT & INTELSAT V.35 scramblers for closed network operation, with additional two modes for
compatibility with FDC and Linkabit proprietary patterns.
8
Deferred alarm at user set service limits (individual Eb/No, BER & Buffer slip thresholds)
8
Frequency
locked clock loops (ie not phase locked) immune to clock hits caused by equipment
such as routers
8
Comprehensive monitoring and status display, with explicit fault descriptions of most significant
fault for Tx & Rx paths
8
P500 1-FOR-N Switch available
allowing mixed interfaces within 1:N system
8
Supported by S2000 multi-product remote M&C system which can provide
centralised log
gathering on a PC
(including logged circuit performance figures, eg Eb/No every 10 mins)
8
Software includes two `User Variables` to accommodate custom user requirements (such as
special alarm handling), allowing special user requested features to be added whilst still keeping
common software
8
Clear display, intuitive menus with `Normal` selections & efficient user interface with full keyboard
8
Tx or Rx paths may be selected as `Off`, muting appropriate alarms in Tx or Rx only applications
8
Three form `C` relays providing prompt Tx/Rx Traffic faults, as well as a prompt unit (equipment)
fault and a deferred alarm.