Section 6: Maintenance and Troubleshooting
6.0 Introduction
This section describes some of the standard maintenance practices that can be performed on
the Mini Compact Outdoor Amplifier and tips to troubleshoot common customer issues.
6.1 Cooling System Maintenance
It is recommended that the cooling system be checked at least once per month. This involves
visually inspecting the fan intakes to make sure that there is no obstructions over the intake.
The Windows-based M&C program can be used to check the amplifier base plate
temperature. The base plate temperature should normally not exceed a 20°C to 25°C rise
above the current outside ambient temperature. If the base plate temperature exceeds this
temperature rise, it is one indicator that the system’s airflow requires maintenance.
The heatsink fins in the exhaust path can be visually inspected for excessive dirt and debris
buildup. If it appears there is excessive debris in the heatsink; the fan tray can be removed for
easy cleaning.
Failure to keep the fans and heatsink clear of debris will void your warranty.
6.2 Fan Removal and Heatsink Cleaning
It is recommended to remove prime AC power from the amplifier when the fan tray is being
removed. However, if necessary, the fan tray can be removed while the amplifier is operating.
Caution should be used to make sure that no clothing or fingers are caught in the fan blades.
Simply remove the four screws from the fan tray and the fan assembly can be removed from
the bottom of the amplifier assembly.
The fans are connected to their power source by weatherized in-line circular connectors. A
replacement fan with connector can be provided for replacement. While the fan tray is
removed, the heatsink fins can be cleaned by spraying compressed air throughout the finned
area. A can of dust remover spray such as that which is found at a computer or electronics
shop will work fine. All debris should be removed before installing the fan tray.
6.2.1 Fan Replacement
The Mini Compact Outdoor SSPA utilizes a two-fan air intake tray, and any maintenance
requiring replacement of the fans should use fan kit L207853-1. This kit replaces the entire
fan tray assembly.
Содержание HPACC3075AC Series
Страница 8: ...8 208143 REV Operations Manual HPA3 Mini Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 12: ...12 208143 REV Operations Manual HPA3 Mini Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 46: ...46 208143 REV Operations Manual HPA3 Mini Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 56: ...56 208143 REV Operations Manual HPA3 Mini Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 82: ...82 208143 REV Operations Manual HPA3 Mini Compact Outdoor SSPA ...